Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM02935
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/12/2008 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 09/29/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 9-29-08 Activity: T08CM02935 Address: 2619 E. Adams St. #2 Applicant: Raymond Ybarra Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. INCLUSIVE HOME DESIGN: (references taken from ANSI 117.1-1998 as amended) 2. Provide an accessible route from the public way extending throughout the entire first floor (except for exempt areas as defined in section 1003.3), 1003.2. 3. Vertical changes in floor elevation may not exceed ¼ inch (½ inch when beveled), 1003.4. 4. Thresholds may not exceed ½ inch in height, 404.2.5. 5. All door hardware must be lever-type or otherwise usable without tight grasping or twisting of the wrist, 404.2.7. 6. Door openings shall have a net width of not less than 30 inches, 1003.5.2.1. 7. Provide all switches, receptacles, and controls within 48 inches of the floor but not less than 15 inches above the floor, 1003.9. 8. Provide blocking in bathrooms for future installation of grab bars around: toilets, showers, and bathtubs, 1003.11.2. FLOOR PLANS: 9. Specify the walking surface outside the exterior doors, R311.4.3. STRUCTURAL PLANS: 10. Provide structural drawings for the guesthouse and the porch. PLUMBING PLAN: 11. Piping shall not be exposed to direct sunlight, IS5-2.2.3. 12. Specify the diameter of the water supply line from the water meter and verify flow capacity to meet the proposed demand, Table 6-6 If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/01/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 10/01/2008 | SUE REEVES | REJECT SHELF | Completed |