Permit Number: T08CM02901
Parcel: 129022240

Address:
2925 E DEVON ST

Review Status: Active

Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU

Permit Number - T08CM02901
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
08/27/2008 ANY NPPO REVIEW Active
08/27/2008 ANY ENGINEERING REVIEW Active
08/27/2008 ANY BUILDING-RESIDENTIAL REVIEW Active
09/25/2008 DAVID RIVERA ZONING REVIEW Denied Revised comments due to plan revisions, 12/11/2008

DSD TRANSMITTAL

FROM: David Rivera
Principal Planner

PROJECT: T08CM02901
2925 E Devon St.
Addition: Porch
Revised DDO comments due to revisions on the plan sheets

TRANSMITTAL DATE: December 11, 2008

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This plan has been reviewed for completeness and compliance with the development Criteria:
A. Residential Use Group, Sec. 6.3.8
1. Family Dwelling "G", subject to: Sec. 3.5.7.1.E, .F, .G, and .H (Ord. No. 8582, §1, 9/25/95; Ord. No. 9443, §1, 11/27/00; Ord. No. 9906, §1, 10/13/03)

2. The interior building setbacks for this development in the R-1 Zone is based on the greatest of 6 feet or 2/3rds the height of the exterior wall adjacent to the property line.

The owner has constructed a trellis structure (porch) along the south and west sides of the existing house. The building setback adjacent to the east property line must be a minimum of 6 feet. The owner proposes a 3'-0" setback from the post to the property line and the overhang encroaches 12" into the 3'-0" setback leaving a 2'-0" setback from the edge of the overhang to the property line. A DDO review and approval is required. If the owner decides to leave the trellis structure and wishes to go through the DDO process the plans must be revised to provide the necessary information to allow the zoning reviewer to do a complete review and DDO comments to the site plan.



3. Two approved site plans were found in records. The plans depict a residential structure but do not depict accessory structures. The new plot plan depicts the residential structure and two accessory structures. While permits are not required for accessory structures under 120 sq ft and no utilities the 10' x 16' structure is greater than 120 sq ft and would have required a permit. The oldest online aerial indicates the accessory structures were in place as of 1998. Provide documentation for the 10'x16' accessory structure.

The owner or applicant may pick up the plans from the DSD ambassador.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.



Previous comments:
DSD TRANSMITTAL

FROM: David Rivera
Principal Planner

PROJECT: T08CM02901
2925 E Devon St.
Addition: Porch and DDO comments

TRANSMITTAL DATE: September 30, 2008

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This plan has been reviewed for completeness and compliance with the development Criteria:
A. Residential Use Group, Sec. 6.3.8
1. Family Dwelling "G", subject to: Sec. 3.5.7.1.E, .F, .G, and .H (Ord. No. 8582, §1, 9/25/95; Ord. No. 9443, §1, 11/27/00; Ord. No. 9906, §1, 10/13/03)

2. The interior building setbacks for this development in the R-1 Zone is based on the greatest of 6 feet or 2/3rds the height of the exterior wall adjacent to the property line.

The owner has constructed a trellis structure (porch) along the south and west sides of the existing house. The building setback adjacent to the east property line must be a minimum of 6 feet. The owner proposes a 3'-0" setback from the post to the property line and the overhang encroaches 2'-2" into the 3'-0" setback leaving an 8" setback from the edge of the overhang to the property line. A DDO review and approval is required. If the owner decides to leave the trellis structure and wishes to go through the DDO process the plans must be revised to provide the necessary information to allow the zoning reviewer to do a complete review and DDO comments to the site plan.

Fire rating of the trellis structure may be necessary. Prior to applying for the DDO the applicant/owner must consult with the residential reviewers for information and requirements for fire rating the porch structure.

3. Two approved site plans were found in records. The plans depict a residential structure but do not depict accessory structures. The new plot plan depicts the residential structure and two accessory structures. While permits are not required for accessory structures under 120 sq ft and no utilities the 10' x 16' structure is greater than 120 sq ft and would have required a permit. The oldest online aerial indicates the accessory structures were in place as of 1998. Provide documentation for the 10'x16' accessory structure.

The owner or applicant may pick up the plans from the DSD ambassador and discuss with the residential plans reviewers the requirements for the fire rating of the trellis structure. The plans must be revised to depict the required construction on the elevation drawings.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.