Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM02831
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/21/2008 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
08/21/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
08/21/2008 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Clarify Keynotes 3 and 4 on Power Plan. |
08/21/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
08/21/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
08/21/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Clarify how the water temperature is to be controlled at the lavatories; two mixing valves appear to be specified. 2. Provide a cleanout for the existing 4" grease waste being connected to the new hand sink (4" lines require a minimum of 3-1/2" cleanouts). 3. Show the location of the new floor sink on the plumbing plan. 4. Correct the size of the waste line for the new hand sink and floor sink on the riser diagram. |
08/21/2008 | ENEWCOM1 | ADA | REVIEW | Passed | |
08/21/2008 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Approved | |
08/26/2008 | CPIERCE1 | WWM | REVIEW | Needs Review | |
08/26/2008 | CPIERCE1 | FIRE | REVIEW | Needs Review | |
08/26/2008 | CPIERCE1 | ENGINEERING | REVIEW | Needs Review | |
08/26/2008 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |