Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM02803
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/07/2009 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T08CM02803 1/7/06 7850 E. HACKBERRY PL. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. PLEASE NUMBER THE SHEETS OF THE PLANS FOUNDATION PLANS: 1. INDICATE THE LOCATION AND IDENTIFY ANY REQUIRED HOLD-DOWN HARDWARE. 2. CONCRETE NOTES ; PROVIDE THE DIAMETER OF THE ANCHOR BOLTS. 3. CONCRETE NOTES ; PROVIDE AN ANCHOR BOLT WITHIN 12" OF THE END OF EACH PLATE. R403.1.6 FLOOR PLANS: 1. PLEASE ILLUSTRATE THE GARAGE DOOR OPENING AND SHOW THE TWO BRACED WALL PANELS WITH THEIR HOLD-DOWN HARDWARE, ADJACENT TO THE OPENING. R602.10 2. SHOW THE LOCATION OF THE EXISTING BLOCK WALL USED TO SUPPORT ONE OF THE NEW NON-BEARING WALLS. 3. DOORS BETWEEN HOUSE AND THE GARAGE SHALL BE MINIMUM 1-3/8" SOLID CORE, PER R309.1 4. NOTE THE WALL BETWEEN THE GARAGE AND THE LIVING AREA IS TO BE COVERED WITH ½", MINIMUM, GYPSUM WALL BOARD. R309.2 STRUCTURAL PLANS: 1. FRAMING PLAN ; WHAT DOES THE WORD "DROP" MEAN? 2. ILLUSTRATE THE LOCATION AND SPECIFY THE SIZE OF THE BEAMS AND HEADERS. 3. SPECIFY LUMBER GRADE AND SPECIES. SPECIFY MANUFACTURER AND SERIES ON GLULAMS AND "I" JOISTS. ELEVATIONS: 1. IDENTIFY THE WALL ELEVATIONS. SECTIONS - DETAILS - MISC. NOTES: 1. DETAIL #1 / FOUNDATION ; PLEASE SHOW THE FOOTING BEARING ON UNDISTURBED SOIL NOT COMPACTED FILL OR PROVIDE A SOIL REPORT ON THE ENGINEERED FILL. R403.1 2. PROVIDE A BUILDING CROSS-SECTION. MORE THAN ONE MAY BE REQUIRED TO CLEARLY ILLUSTRATE HOW THE STRUCTURE IS BUILT. THE CROSS SECTION SHOULD BE TAKEN PARALLEL TO THE RAFTERS SHOWING THE RAFTER CONNECTIONS. 3. DETAIL #7 / FRAMING ; THE TOP CHORD APPEARS TO BE CUT/NOTCHED. PLEASE AVOID THIS. AMEND THE DRAWING. 4. CROSS-SECTIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLAN AND FRAMING PLANS. MECHANICAL PLANS: 1. PROVIDE A PERMANENTLY INSTALLED SOURCE OF HEAT. IS THE AIR CONDITIONER A HEAT PUMP? R303.8 2. PLEASE SIZE THE DUCT TO THE CLOSET AND CRAFT ROOM. 3. PROVIDE FRESH AIR TO THE OFFICE. R303.1 EXCEPTION 1 (4 BED ROOM ) 4. THE MECHANICAL PLAN IS LABELED "MECHANICAL / GAS". IS GAS IN THE PLAN? ENERGY EFFICIENCY: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
| 12/26/2008 | GERRY KOZIOL | WWM | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/23/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/23/2009 | SUE REEVES | REJECT SHELF | Completed |