Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM02792
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/27/2008 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. 1/8" LETTERING ON ALL DRAWINGS REQUIRED UNLESS A WRITTEN APPEAL IS APPROVED BY THE BUILDING OFFICIAL, JESSIE SANDERS. THIS APPROVED APPEAL MUST ACCOMPANY DRAWINGS SUBMITTED FOR CHECKING. REFERENCE ARCHITECTURAL AND STRUCTURAL DRAWINGS. PLEASE PROVIDE AN APPROVED BUILDING OFFICAL APPEAL APPROVAL. 2. ALL DEFERRED SUBMITTALS MUST BE APPROVED BY THE BUILDING OFFICIAL, JESSIE SANDERS. THIS APPROVAL MUST ACCOMPANY DRAWINGS SUBMITTED FOR CHECKING. REFERENCE PLATED WOOD TRUSSES. 3. SHEET A.4; SECTIONS 1, 3 AND 4: FOR DETAILS 3 AND 4: TRUSS CONNECTION CAN NOT BE DIRECTLY TO WEB. CONNECT TOP OR BOTTOM CORD WITH BRACING AND CONNECT WALL BRACING TO TOP OR BOTTOM CORD. FOR DETAIL 1: PROVIDE 2X4 WEB BRACING AT EACH FASCIA AND CEILING FRAMING CONNECTION. DIRECT WEB ATTACHMENT IS NOT ACCEPTABLE BY MANUFACTURER. 3. DENOTE ASSURANCE THAT SERVICE COUNTER WILL HAVE AN ACCESSIBLE COUINTER SECTION. |
12/18/2008 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
12/19/2008 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
12/19/2008 | ROBERT SHERRY | WATER | REVIEW | Denied | Comment not addressed. Provide a letter from Tucson Water confirming that the use of a 5/8" water meter will be allowed for this project (24.5 fixture units equates to a demand of 17 GPM). |
12/19/2008 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
12/19/2008 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | DATE: December 19, 2008 SUBJECT: Site Plan TO: KBP Architecture LLC LOCATION: 7865 E Speedway Blvd, T13S, R14E, Sec 30 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM02792 (First Review) 1. Need Floodplain Use Permit to be submitted along with next submittal of Building Permit. 2. Include copy of Drainage Report with established minimum finished floor elevation for proposed restaurant. 3. Unable to approved Building Permit until all Floodplain Use requirements have been met. 4. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
12/19/2008 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | Based on further review, this building permit is approved. |
12/22/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The revised waste and vent riser diagram appears to show a 2" vent located between the air intake for the flow control device and the hydromechanical grease interceptor. Revise the drawing to comply with the requirements of Section 1014.2.1, UPC 2006. 2. The scupper sizing calculations provided for the north and south roof areas appear to have been done using the 2003 UPC which does not meet the requirements of the 2006 UPC. In addition, the projected area of the north roof area is smaller than shown on the plans and neither area calculation includes the effect of the surrounding parapets. Reference: Sections 1101.11.1, 1101.11.2.1, and 1106.4, UPC 2006, and Section 1611.1, IBC 2006. 3. The scupper sizing calculations provided for the center roof area appears to have been done using the 2003 UPC which does not meet the requirements of the 2006 UPC. In addition, the area calculation does not include the effect of the surrounding walls and parapets. Reference: Sections 1101.11.1, 1101.11.2.1, and 1106.4, UPC 2006, and Section 1611.1, IBC 2006. |
12/23/2008 | GERRY KOZIOL | WWM | REVIEW | Denied | 1)EL POTPSINO RESTAURANT- ISSUED W/ GREASE INTERCEPTOR 2)REPLACEMENT PROJECT- NEEDS WASTEWATER CREDIT REVIEW FOR PREV ISSUED PERMITS PT07S01081 & PT07S01082 3)NEEDS WWM 3RD FLOOR REVIEW/ILENE DECKARD REVIEW OF EASEMENTS USE AGREEMENTS DKT 12588 PG 1535 4)NEED WWM 3RD FLOOR MANHOLE TAP REVIEW & PERMIT/ YVONNE SUAREZ |
12/23/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide energy code compliance calculations for the building envelope. The calculations shall be for "Pima County < 4,000 feet", not the town of Pima, Arizona. Reference: Section 101.4, International Energy Conservation Code 2006. 2. Provide structural calculations for the connection of the 4"x8" wood beam to the roof framing (Detail 2/A.4). The submitted calculations cover the ΒΌ" bent plate hanger for the threaded rod but not the connection of the 4"x8" beam. Reference: Section 302.1, IMC 2006. |
12/29/2008 | JEFF DRUMM | LANDFILL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/21/2009 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
01/21/2009 | SUE REEVES | REJECT SHELF | Completed |