Permit Number: T08CM02789
Parcel: 13225069F

Review Status: Completed

Review Details: SITE

Permit Number - T08CM02789
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/22/2008 RBROWN1 ADA REVIEW Passed NOT A COT PROJECT
08/22/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 1. accessible route concrete walk needs to be extened to landing of ramp.
2. Detectable warning strip not required if accessible route ramps leads to landing iof a ramp.
3. Accessible parking has no connection to accessible route and ramp landing. This is required.
4. See suggested sketch attached to drawing.
5. Landing at top of ramp must be hace a clear turnaround 2'-6" radii circular space.
6. Bottom of main accessible signage to be 7' A.F.G.
End of review
08/25/2008 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: T08CM002789
3907 E. Irvington Rd.
Modular Site Plan

TRANSMITTAL DATE: 08/25/08

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Provide the existing uses of both properties.

2. Provide existing parking calculations for all uses on both sites together with the new medical services out patient.

3. Clearly indicate the surfacing materials for the vehicular use area for the new parking spaces and existing vehicular use area for the entire lot on which the new modular building is located. (Show entire lot)

4. The pedestrian circulation path is not complete along the east side of the new modular building. Must connect to the indicated handicap ramp.

5. Provide an accessible pedestrian circulation path from the handicap parking spaces to the new modular building.

6. A minimum 4' sidewalk is required between a PAAL and a building and between a parking space accessed by a PAAL and a building. Not complete along the east side of the building nor along the west side of the building.

7. Clearly indicate the widths of all sidewalks and required pedestrian refuge areas. A pedestrian refuge area is required between a building and a PAAL with a minimum width of five (5) feet. (Along the east side of the building)

8. Provide a copy of the last approved site plan clearly indicating the existing uses as being approved. The last approved site plan provided indicates Sundt Corp. was the entire site. Documents provided indicate TEP has s taken over a portion of this site. Clarify.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\T08CM02789.doc
08/26/2008 DAVE MANN FIRE REVIEW Approved Verify fire rating of mobile unit due to proximity to property line.
09/05/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. Submit a separate landscape plan for the site per DS 2-07.0. in order to verify that landscaping meets minimum requirements. Indicate all improvements, including required landscaping and irrigation details.

2. Submit a copy of the last approved landscape plan for the site.

3. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a Provide required canopy trees within the parking area. Include canopy trees for the seven (although the site plan indicates four) parking spaces shown to the south of existing building #3901, which were not shown on the last approved site plan submitted, or provide additional information that this portion of the parking lot has been previously permitted (see comment #1).
09/08/2008 PETER MCLAUGHLIN NPPO REVIEW Passed
09/11/2008 PAUL MACHADO ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/24/2008 CPIERCE1 OUT TO CUSTOMER Completed