Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM02730
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/08/2008 | VFLORES1 | ZONING HC SITE | REVIEW | Needs Review | |
| 08/08/2008 | VFLORES1 | WWM | REVIEW | Needs Review | |
| 08/08/2008 | VFLORES1 | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 08/08/2008 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 08/08/2008 | VFLORES1 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review | |
| 08/08/2008 | VFLORES1 | WATER | REVIEW | Needs Review | |
| 08/08/2008 | VFLORES1 | MECHANICAL-COMMERCIAL | REVIEW | Needs Review | |
| 08/08/2008 | RBROWN1 | ADA | REVIEW | Passed | |
| 08/11/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PER IBC 3409.7, GIVE A COST BREAKDOWN OF THE PROJECT, INDICATING COST OF ACCESSIBILITY ALTERATIONS (MAXIMUM REQUIREMENT OF 20%). 2. SHEET A1.0; FLOOR PLAN: PER IBC SECTION 3409.8.5 AND SECTION 1010.2, ACCESSIBLE EGRESS RAMP SLOPE WILL NOT EXCEED 12.5%. RAMP SLOPE INDICATED AT 17.88%. REVISE AS REQUIRED. 3. SHEET A1.0; FLOOR PLAN: NOTE TO 'FIELD VERIFY RAMP FOR ACCESSIBILITY....' MUST BE VERIFIED ON THESE DOCUMENTS. 4. SHEET A3.1: REMOVE NEW WALL/NEW PARTIAL WALL LEGENDS FROM SHEET. |