Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T08CM02654
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/04/2008 | TERRY STEVENS | ZONING | REVIEW | Passed | |
| 08/05/2008 | RBROWN1 | ADA | REVIEW | Approved | 6 AUGUST 2008 T08CM02654 REVIEWED BY RON BROWN ACCESSIBLE REVIEW ADAAG 1994 EDITION DENIED: SEE COMMENTS BELOW SHEET X1.2 1. All curb and side walk ramps to comply with ADAAG sections 4.7 and 4.8. Provide large scale details of all different types of ramps showing dimensions, slopes, accessible routes and detectable warnings. a. Detectable warnings for all curb ramps to be in compliance with section 4.7.7 and sized accordingly. b. Detectable warnings at all sidewalk ramps shall be in compliance with section 4.29.5 and sized accordingly 2. All accessible parking to comply with ADAAG section 4.1.2 (5) (a) and 4.6. Show large scale detail showing slopes, dimensions, "Van Accessible" spaces, curbs, ramps, detectable warnings, and accessible routes and etc a. All detectable warnings to be placed at the end of all parking aisles as per section 4.29.5. b. Provide a physical barrier at the front of all accessible parking spaces to comply with section 4.29.5. c. Show "Van Accessible" space. 3. The crossing angle of all marked crossings, with exception of the most westerly crossing, presents a situation for physically and visually empaired persons that makes the already hazardous crossing even more hazardous because of their increased distance and additional time to cross as compaired to a perpendicular crossing. Please adjust these angles to something shorter, less hazardous and acceptable. a. All ramps for crossings to comply with note 1 above. 4. Provide sign post detail for accessible parking and show locations of all signs on all site plan. 5. Detail 10/x1.4: a. Contact "Park Wise" for exact sign format and graphic layout. b. Provide a "Van Accessible" sign at identified van accessible spaces. c. Fine is now $532.00 5. Identify accessible route through out new campus addition and connection to existing accessible route as required by ADAAG sections 4.1.2., 4.1.3, and 4.3 END OF REVIEW |
| 08/05/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Passed | |
| 08/07/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
| 08/15/2008 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 08/15/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Passed | |
| 08/27/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Passed |