Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM02578
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. 1/8" LETTERING IS REQUIRED ON ALL DRAWINGS UNLESS A WRITTEN APPEAL IS APPROVED BY THE BUILDING OFFICIAL, JESSIE SANDERS. THIS APPROVED APPEAL MUST ACCOMPANY DRAWINGS SUBMITTED FOR CHECKING. 2. SHEET A2-2; DETAILS 3 AND 5: PROVIDE VERTICAL GRAB BAR PER FIG. 604.5.1 OF ICC/ANSI A117.1-2003. 3. PROVIDE BRACING OF INTERIOR PARTITION WALLS DUE TO LOADING DESCRIBED IN IBC 1607.13. |
| 08/06/2008 | DAVE MANN | FIRE | REVIEW | Denied | Fire rated exit corridor or fire sprinklers are required per IFC Table 1017.1. |
| 08/06/2008 | RBROWN1 | ADA | REVIEW | Passed | |
| 08/07/2008 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Denied | 1. REFER TO BUILDING COMMENTS. |
| 08/13/2008 | GERRY KOZIOL | WWM | REVIEW | Denied | NEEDS 5TH WASTEWATER 5TH FLOOR CREDIT EVALUATION |
| 08/19/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). (A 3/32" font may be allowed with an appeal to the building official.) Reference: Section 106.1.1, IBC 2006. 2. Show how the outdoor air intake (Section 6.2.5.4, ASHRAE 62.1-2004) for the AC units (multi-zone recirculating systems) was calculated without providing the primary airflow data noted in Section 6.2.5.1, ASHRAE 62.1. 3. Clarify how detail 206/P2.2 relates to the installation of the ductless A/C unit, F-1, in room 002. Note that detail 104/M2.4 is also unclear as to the condensate disposal. Reference: Sections 106.3.1 and 307.2, IMC 2006. |
| 08/19/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 08/20/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). (A 3/32" font may be allowed with an appeal to the building official.) Reference: Section 106.1.1, IBC 2006. 2. Clarify how detail 205 relates to the mop sink, P-5. Reference: Section 103.2.3, UPC 2006. 3. Clarify the termination of the T&P relief piping for WH-1; it is not shown on the plumbing plans as noted in detail 201. Reference: Section 103.2.3, UPC 2006. 4. Clarify the waste and vent connection of P-6 in room 008. Reference: Section 103.2.3, UPC 2006. 5. Provide the minimum plumbing facilities (e.g. a drinking fountain) required by Table 2902.1 and Section 2902.2, IBC 2006, for business occupancy. |
| 09/02/2008 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |