Permit Number: T08CM02549
Parcel: 13316021C

Address:
6616 E GRANT RD

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T08CM02549
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2009 DAVE MANN FIRE REVIEW Denied Sheet SP 1.0 Shows the build as sprinklered in Delta 2 for area but unsprinklered but unsprinklered in Delta 2 for code review. Please clarify.

The egress width was also calculated for sprinklers.

If unsprinklered please change plans and calculations and show hydrant locations and fire lanes per current building plans and Fire Code and Development Standards.
08/31/2009 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Taco Bell - 6616 E. Grant Rd.
T08CM02549
Site Plan (3rd Review)

TRANSMITTAL DATE: August 31, 2009


COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for code compliance.

2. The SVT's are not shown correctly. This comment was not addressed correctly. The existing SVT's are required to be shown on the plan also. D.S.2-02.2.1.A.10 Zoning acknowledges that the existing sight visibility triangles (SVT's) are shown on the plan. Based on the future curb location show the future SVT's on the plan.

3. Zoning acknowledges the provided cross access agreement document. This document must be recorded prior to approval of the site plan. D.S.2-02.2.2.A.4 Provide a copy of the recorded cross access agreement. As the required 22 vehicle parking spaces for Taco Bell are provided on site a cross parking agreement is not required.

4. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t08cm02549-3rd

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
09/02/2009 RONALD BROWN ZONING HC REVIEW Approved
09/08/2009 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.
09/08/2009 SREEVES1 PLUMBING-COMMERCIAL REVIEW Needs Review
09/08/2009 LOREN MAKUS ENGINEERING REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
09/08/2009 SUE REEVES OUT TO CUSTOMER Completed