Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T08CM02511
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/29/2008 | MARTIN BROWN | FIRE | REVIEW | Denied | Please indicate location of existing fire hydrant(s) with dimensions to property line. |
| 07/29/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Hamstra Heating & Cooling - New Office Building T08CM02511 Site Plan (1st Review) TRANSMITTAL DATE: July 29, 2008 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the area of expansion only. 2. D.S.2-02.2.1.A.6 Provide overall dimension for the proposed building within the footprint on the plan. 3. D.S.2-02.2.1.A.7 Provide a building setback dimension in regards to future curb for Bilby Road. 4. D.S.2-02.2.1.A.9 Indicate on detail 10/A0.2 how lighting will be provided for the bicycle parking. 5. D.S.2-02.2.1.A.10 Provide future sight visibility triangles (SVTs) for the entrance off of Bilby Road based on future curb location. 6. D.S.2-02.2.1.A.12 Provide a dimension from the top of curb access ramp to the building to verify that a minimum 4'-0" sidewalk is provided between the ramp and building. 7. D.S.2-02.2.1.A.12 Per D.S. 2-08.3.1 provide a continuous pedestrian/accessible route to the refuse enclosure. 8. D.S. 2-02.2.1.A.13 If applicable provide the location, type, size and height of existing and proposed freestanding signage and billboards. 9. D.S. 2-02.2.1.A.20 If applicable show all easements of record graphically on the plan together with recording docket and page reference. 10. D.S. 2-02.2.1.A.25 If applicable provide proposed freestanding lighting layout and type. Provide a detail; list the height of pole and type of lighting. 11. D.S. 2-02.2.1.A.31 Provide the existing use on the plan. 12. Provide a note on the plan stating "Per LUC Section 2.8.5.5.B.2 Compatible Use Zones for the TIA Environs. CUZ-2. Structures or uses with fifty (50) or more employees must develop an emergency evacuation plan and training program and implement it as approved by the Fire Department." 13. Additional comments may be forth coming once the last approved site plan is provided. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t08cm02511 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents. |
| 07/31/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 31 JULY 2008 T08CM02511/HAMSTRA HEATING AND COOLING REVIEWED BY RON BROWN ACCESSIBLE REVIEW 2006 IBC/ICC 117.1 DENIED: SEE COMMENTS BELOW I. SHEET A0.1 A. DENOTE GOVERNING ACCESSIBILITY CODE; 2006 IBC/ICC 117.1 FOR PRIVATE PROPERTY, DENOTE RIGHT OF WAY ACCESSIBILITY STANDARDS; COT DOT STANDARDS FOR CURB RAMPS AT DRIVE WAYS. B. RAMP DETAIL AT FRONT ENTRANCE DOES NOT WORK. EITHER REDESIGN ENTRY WITH CURB RAMP AS PER ANSI 117.1, SECTION 406 OR RELOCATE MARKED CROSSING WITH ACCESSIBLE PARKING TO OTHER SIDE OF DRIVE ENTRANCE. C. PROVIDE DETECTABLE WARNINGS AT BOTH SIDEWALK RAMPS ON EITHER SIDE OF ENTRANCE TO INTERIOR LOADING ZONE. D. CHANGE ALL NOTES FROM ADA STANDARDS (S/B ADA ACCESSIBLE GUIDELINE STANDARDS ADAAG) TO 2006 IBC/ICC 117.1 ACCESSIBLE STANDARDS. E. IDENTIFY "VAN ACCESSIBLE" SPACE. II. SHEET A0.2: A. DETAILS 12 AND 13: DELETE ALL REFERENCE TO ADA STANDARD 4.29.2. B. DETAIL 14: DOES NOT WORK, REDESIGN OR RELOCATE. ALL RAMPS ARE TO COMPLY WITH 2006 IBC/ICC 117.1 STANDARDS NOT ADA STANDARDS. C. DETAIL 2: CHANGE FINE TO $532.00 AND ADD "VAN ACCESSIBLE SIGN TO POST. END OF REVIEW |
| 08/04/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Provide future sight visibility triangles based on future curb location D.S.2-02.2.1.A.10. 2. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. |
| 08/05/2008 | ANDREW CONNOR | NPPO | REVIEW | Approved | Exception |
| 08/26/2008 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | August 27, 2008 T08CM02511 Hamstra Heating & Cooling Please address the following comment in the drainage report and make any required revisions in the site plan. Demonstrate and discuss that the retention and detention requirements will be met with discharges generated on site. Off-site discharges may be changed by future development. If you have any questions, please contact me at loren.makus@tucsonaz.gov or 520.837.4927 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/08/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |