Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM02437
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/10/2008 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T08CM02437 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007, the 2006 UPC with amendments on 7/10/2007 and effective 1/1/2007 the Inclusive Home Design. All plans should reference these codes. Adopted amendments are found at: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html GENERAL NOTES: " All code references to the International Residential Code shall be changed from 2003 to 2006 with appropriate paragraph references. Revise references at Notes 2, 3, & 10 sheet A3.0. " " Show compliance with the Inclusive Home Design Ordinance adopted by the City of Tucson on 10/16/2007. Accessible route, door width, changes in floor elevation, door hardware, electrical outlet reach range, grab bar reinforcement, etc. FOUNDATION PLANS: 1. Revise the Alternate Braced Wall Panel notation (sheet A1.2) showing a device and an installation method that provides the required 1800 LBS uplift capacity, R602.10.6. The HPAHD22 is rated less than 1800 LBS when installed with end distance less than 8" and with fewer than 23 -16d nails. 2. Provide consistent notation. The PAHD42 hold-down model shown on the Foundation Plan is not defined on the Braced Wall Panel Schedule, sheet A1.2. The PAHD42 is rated less than required 1800 LBS when installed with end distance less than 8". FLOOR PLANS: 1. Clarify if the east wall is existing or new, sheet A1.3, R106.1.1. STRUCTURAL PLANS: 1. Show interior wall line bracing at intervals not exceeding 35' (50' exception) from exterior wall lines, R602.10.1.1. Show location and method for the Main House. 2. Provide joist sizes and spacing in compliance with Table R802.4. The 2x8 ceiling joist are undersized in some areas. SECTIONS - DETAILS: 1. Clarify if the entire Bay Area is being removed, Note 5 sheet A1.0, R106.1.1. 2. Show the braced wall sheathing thickness rather than a size larger than the panel width, sheet A1.2, R106.1.1. 3. Provide a detail for Builder skylights showing materials, fasteners and flashing, or an ICBO number, R106.1.1. 4. Show fiber-cement board or glass mat gypsum backers for tiled walls in tub and shower areas, sheet A1.2, R702.4.2. PLUMBING PLANS: 1. Provide a plumbing design using a single code, 2006 UPC or 2006 IRC. The plans may reference one of these codes on the Plumbing sheets. Revise the IRC references at four locations or change all UPC references and calculations. 2. Provide water hammer arresters wherever quick-closing valves are installed in a water distribution system. The devices should conform to ASSE 1010-2004. Water hammer arresters are required for clothes washer, dishwasher and refrigerator water connections, IRC P2903.5. 3. Provide water pressure range, developed length, and water meter size, UPC 610.8, Table 6-6. 4. Consider revising the fixture unit schedule showing 1.0 fixture unit for the additional hose bibs after the first rated at 2.5, UPC Tables 6-5 & 6-6. 5. Size the water meter, service pipe and branch lines in compliance with UPC 610.3. A dwelling with 45 fixture units requires a 1" water meter and a 1-1/4" service pipe. Branch pipes may be reduced in size as the downstream fixture count allows, 610.8, Table 6-6. 6. Show the underground gas in an approved sealed & vented conduit in conformance with UPC 1211.1.6 rather than IRC G2415.11. MECHANICAL PLANS: 1. Provide an equipment specification list including Mech. Unit #3, M1302.1. 2. Provide return air duct and register sizes, M1602. Minimum duct/register size: heat pump or air conditioner - 6 SQ IN / 1000 BTU, M1403.1 (1 ton cooling = 12,000 BTU). Show the return air duct sizes between the three Mech. Units and room opening. ELECTRICAL PLANS: 1. Show locations of smoke alarm, R313. Note that all smoke alarms must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. When ceiling finish materials are removed in existing construction, existing bedrooms shall be in compliance. When ceiling finish materials are not removed, existing bedrooms may be equipped with battery operated smoke alarms, R313.2. 2. Smoke alarms are required outside each separate sleeping area, R313.2. 3. Revise the electrical load calculation for Sub-panel 'B' to include Mech. Unit #3, E3502.2. 4. Show sub-panel feeder conductor and conduit sizes on the Riser Diagram, E3605. 5. Show receptacle outlets with no point along the wall (fixed glass panels) more than 6' from a receptacle outlet, E3801.2. Add or relocate the floor receptacle between the fireplace and Living Room exterior doors. OUTDOOR LIGHTING CODE 1. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. 2. Provide cut sheets for all full cut-off fixtures showing the lamp placement and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). Fixtures are only exempt from the total lumen budget if both of the full cut-off FCO style and located under overhangs, OLC 5.1.2. INTERNATIONAL ENERGY CONSERVATION CODE: 1. Show a maximum value of U=0.75 for the skylights, or provide a REScheck report if using a greater value, N1101.2. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |