Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08CM02435
Parcel: 112074030

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T08CM02435
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2008 GERRY KOZIOL WWM REVIEW Approved
08/11/2008 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T08CM02435

2909 E. CHULA VISTA DR. 8/12/08

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, IECC AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


FOUNDATION PLANS:

1. PLEASE SHOW DETAIL 2/3 AS BEING TAKEN THROUGH A PORCH FOOTING.

FLOOR PLANS:

1. PLEASE LABEL THE 4040 BY THE BATH TUB TEMPERED. SEE R308.4 ITEM 5

STRUCTURAL PLANS:

1. PROVIDE HEADERS FOR OPENINGS.

2. PROVIDE MANUFACTURER'S DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS CALCULATIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS.

3. DETAIL GABLE END BRACING CONNECTIONS. THIS MIGHT COME WITH THE TRUSS PACKAGE.

ELEVATIONS:

1. THE ELEVATIONS SHOW PAINTED CMU, 4416, WHICH IS INDICATIVE OF A VENEER WHICH WOULD CONFLICT WITH DETAIL 1/3's STUCCO. PLEASE RESOLVE, STUCCO OR VENEER?

2. PLEASE DIMENSION THE WALL HEIGHT.

SECTIONS - DETAILS - MISC. NOTES:

1. 1/3 ; THE FOOTING IS DIMENSIONED AS 16" WIDE WHICH CONFLICTS WITH THE NOTE WHICH SAYS 24" WIDE. PLEASE RESOLVE.

2. 1/3 ; PLEASE PROVIDE A REINFORCED BOND BEAM AT THE TOP OF THE STEM WALL. SEE R403.1.3.1

3. 2/3 ; HOW IS THE FLOOR CONNECTED TO THE FOOTING? #4 VERTICAL, LONGER ANCHOR BOLT, ….

PLUMBING PLANS:

1. PLEASE JUSTIFY THE EXISTING WATER LINE'S ABILITY TO SUPPLY BOTH THE EXISTING FIXTURES AND THE PROPOSED NEW BATH ROOM'S FIXTURES.

ELECTRICAL PLANS:

1. PLEASE CHECK THE MATH FOR THE ELECTRICAL LOAD CALCULATIONS.

2. CIRCUIT 1 THAT YOU'VE USED FOR GENERAL LIGHTING IS ALREADY USED FOR THE WATER HEATER.

3. CIRCUIT 2 IS USED FOR GENERAL LIGHTING AND IS 15 AMPS WHICH IS NOT APPROPRIATE FOR THE BATH ROOM RECEPTACLES. SEE E3603.4 ALSO SEE THE EXCEPTION FOR E3603.4

4. THE LEGEND INDICATES A HANGING LIGHT FIXTURE OVER THE BATH TUB. THE LIGHT FIXTURE IS REQUIRED TO BE 8 FEET ABOVE THE TOP OF THE BATH TUB. PLEASE LABEL THE LIGHT TO BE USED AS APPROVED FOR USE IN A DAMP AREA. SEE E3903.10

5. PROVIDE AN ELECRRICAL DRAWING FOR THE RE-WIREING OF THE HOUSE AS NOTED AT THE BOTTOM OF THE PANEL SCHEDULE.




IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 837-4910

Final Status

Task End Date Reviewer's Name Type of Review Description
08/15/2008 VFLORES1 OUT TO CUSTOMER Completed