Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T08CM02382
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/14/2008 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 07/15/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
| 07/16/2008 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | SEE PREVIOUS WORKFLOW |
| 07/21/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 07/23/2008 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Electrical Plan Check For 310 W Alameda St , T08CM02382 The following items need to be addressed, 1. Provide service receptacles for HVAC equipment on roof as required in NEC 2005 210-63, and circuit according. 2. Several of the existing panels feeding from MSWB-1 on sheet E2-0 are labeled 120/208v and should be 277/480V. Ray T Majuta Electrical Plan Check City of Tucson DSD 7/26/08, 520/837/4988 |
| 08/05/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Section 403.3, IMC 2006, as amended by the City of Tucson allows the use of the ASHRAE 62-1-2004 ventilation calculation procedure provided that the default occupant densities and combined outdoor air rates are used. 2. Clarify how the use of the ASHRAE 62.1-2004 category, "General / Storage Rooms", is appropriate for a printing zone. Reference: Section 106.3.1, IMC 2006. 3. Provide information to clarify how the replacement HVAC units compare to the existing HVAC units for weight and what, if any, structural changes are to be made to the roof framing. Reference: Section 3021, IMC 2006. 4. Indicate the proposed locations of the new duct smoke detectors. Reference: Sections 106.3.1 and 606.2, IMC 2006. 5. Provide a minimum R-value of R-8 for the wrapped exterior ductwork; paragraphs 2.02A and 3.03A, Section 15080 of the mechanical specifications provide an R-value of only 7.4 h*ft^2*F/Btu. 6. Provide fire/smoke dampers for the penetration of the return air shafts. Specify the required rating for the dampers. Reference: Sections 106.3.1 and 607.5.5, IMC 2006. |
| 08/06/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide the F- and T-rating required for the penetration of the shaft by the natural gas pipe and show how the pipe is to be supported on either side of the penetration. (Note: the installer shall provide documentation of the approved penetration system being used for the field inspector to compare with the actual installation.) Reference: Section 1501.1, UPC 2006. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/08/2008 | VFLORES1 | OUT TO CUSTOMER | Completed |