Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T08CM02371
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/18/2008 | GERRY KOZIOL | WWM | REVIEW | Denied | NEEDS WASTEWATER 8TH FLOOR REVIEW OF LOCATION AND METHOD OF CONNECTION TO PUBLIC SEWER |
| 08/18/2008 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1. A Native Plant Preservation Plan per Development Standard 2-15.3.0 is required for all single family residential development on lots recorded after March 24, 1997 according to the methodology selected by the applicant as outlined in Plant Preservation Requirements LUC 3.8.6. Submit NPPO plan with appropriate information. 2. LUC 3.8.4.4 Preparation of all elements of the Native Plant Preservation Plan and on-site monitoring as required under LUC 3.8.6.7.D shall be performed by a plant professional, such as: " An arborist certified by the International Society of Arboriculture. " A landscape architect. " A horticulturist, biologist, or botanist with a minimum B.A. or B.S. in an appropriate arid environment natural resource field. |
| 09/11/2008 | DAVE MANN | FIRE | REVIEW | Denied | Fire sprinklers required. |
| 09/19/2008 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T08CM02371 9/19/08 804 N. SHEPHERD HILLS PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. PLEASE DIRECT SEWER TO THE PUBLIC SEWER, UPC 713.5 FLOOR PLANS: 1. SECTION LINE C / 3 ; THE ARROWS THAT INDICATE THE DIRECTION OF VIEW APPEAR TO BE POINTING THE WRONG WAY. 2. IDENTIFY CEILING HEIGHTS IN ALL AREAS ON FLOOR PLAN. IF SLOPED CEILING, NOTE AVERAGE HEIGHT. STRUCTURAL PLANS: 1. FRAMING PLAN / 6 ; THE DETAILS ARE CALLED OUT AS BEING ON SHEET 10. PROVIDE SHEET 10. SHOULD IT BE SHEET 6.1 ? 2. PROVIDE MANUFACTURER'S DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS DATA SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. ELEVATIONS: 1. KEYNOTE #E / 4 ; PLEASE UPDATE THE LISTING NUMBER. THE NUMBER USED IS A LEGACY NUMBER NO LONGER IN USE. 2. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL VENTS NEEDED TO COMPLY. OR NOTE THE INSULATION IS TO BE PLACED AT THE TOP CHORD OF THE TRUSSES. 3. NOTE AND DIMENSION THAT THE FIREPLACE CHIMNEY MUST TERMINATE A MINIMUM OF 2' ABOVE ANY POINT OF ROOF WITHIN 10' MEASURED HORIZONTALLY AND NOT LESS THAN 3' ABOVE THE POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF, PER FIGURE 1001.1 . SECTIONS - DETAILS - MISC. NOTES: 1. 2 / 6.1 ; PROVIDE 19 / 10. SHOULD IT BE 19 / 6.1 2. 15 / 6.1 ; PROVIDE 14 / 11 3. 17 / 6.1 ; DOES SIMPSON MAKE A HSUR /612? PLEASE PROVIDE A LISTING. 4. 21 / 6.1 ; PROVIDE THE JOIST HANGER FOR THE I-JOIST. PLUMBING PLANS: 1. PLEASE SIZE THE AAVs . 2. KITCHEN SINKS ARE 2 DFUs PER TABLE 7-3 AND 1 ½" HORIZONTAL DRAINS ARE LIMITED TO 1 DFU PER TABLE 7-5. PLEASE CONSIDER 2". 3. PLEASE SIZE THE MASTER BATH LAVATORY BRANCH DRAINS. 4. PLUMBING ISOMETRIC / 9 ; PROVIDE A TRAPPED CONNECTION TO AN INDIRECT CONNECTION FOR THE ICE MAKER TO BUILDING DRAIN. UPC 801.1, 801.2, 803.0, 804.1 5. PLEASE SPEC THE ICE MAKER. 6. PROVIDE THE WATER METER SIZE. 7. SIZE THE WATER SERVICE LINE FROM THE METER TO THE FIRST HOSE BIB. 8. WHERE DOES THE LEFT SIDE OF THE HOUSE CONNECT TO THE WATER DISTRIBUTION SYSTEM? 9. PLEASE CHECK THE TOTAL OF THE GAS INPUT RATES. I GOT 532,000. 10. PLUMBING NOTE #10 / 9 ; WATER HAMMER PROTECTION IS REQUIRED ON ALL QUICK-CLOSING VALVES, ie ICEMAKERS, REFRIGERATOR ICE MAKERS, FLUSH VALVES, ETC. UPC 609.10, IPC 604.9, IRC P2903.5 11. PLEASE ADD A NOTE RE: WATER CONSERVING PLUMBING FIXTURES. MECHANICAL PLANS: 1. PLEASE CHECK THE SIZING OF THE 12" X 20" SUPPLY DUCT FROM FC-1 . 2. MECHANICAL SPECIFICATION #9 / 8 ; PLEASE CHECK THE DUCT INSULATION R-VALUE. SEE IECC 403.2.1 AND IRC N1103.2.1 ELECTRICAL PLANS: 1. CIRCUITS 9,11 DON'T APPEAR APPROPRIATE FOR THE OVEN. SHOULD THEY BE 5,7 ? 2. PLEASE CLARIFY THE COOK TOP'S CIRCUIT NUMBER ON THE PLANS. 3. CIRCUIT 5,7 IS LABLED DBL OVEN ON THE PANEL SCHEDULE BUT IT IS USED FOR CONDENSER #2. ALSO, PLEASE CHECK THE LOCATION OF THE DISCONNECT AND THE LOCATION OF CONDENSER #2 ON THE MECHANICAL PLAN AND ON THE SITE PLAN. 4. PLEASE ASSIGN A CIRCUIT FOR THE DRIVEWAY LIGHTS OR TRANSFORMER. THEY APPEAR TO BE LOW VOLTAGE. ENERGY: 1. JUSTIFY THE 8" INSULATION IN THE RAFTERS OVER THE PANTRY AND THE GARAGE STORAGE OR SHOP. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
| 09/24/2008 | JEFF DRUMM | LANDFILL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/01/2008 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 10/01/2008 | SUE REEVES | REJECT SHELF | Completed |