Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: POST 3RD PARTY REVIEW
Permit Number - T08CM02322
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/05/2009 | DAVE MANN | FIRE | REVIEW | Denied | There is a note on sheet 1s regarding fire sprinklers. Please include the following fire sprinkler design criteria to the plans. 1. Flow data (static pressure, residual pressure, GPM) Available from the Fire Department (520) 791-3234 2. The standard to be used in development of sprinkler system. (NFPA 13, NFPA 13R, or NFPA 13D) 3. The hazard classification of the building, including any special hazards. 4. The density required of the water supply. |
| 05/05/2009 | GERRY KOZIOL | WWM | REVIEW | Denied | need 5th floor credit evaluation |
| 05/07/2009 | SREEVES1 | ZONING | REVIEW | Needs Review | |
| 05/07/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: May 7, 2009 SUBJECT: Arquitecto E.J. Ornelas TO: Randy LOCATION: 17Address, T14S, R14E, Section 18, Ward 5 N Alvernon Way REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T0CM02322 (Third Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the site plan with the next submittal. Site Plan: 1. Full code compliance review required per zoning, full site review will be completed. 2. Lot combo request and recorded Covenant Regarding Development and Use of Real Property required. 3. Complied 4. Revise property description accordingly once lot combo has been completed. 5. Complied 6. Verify that all necessary existing and future sight visibility triangles are shown within site plan per D.S. 2-02.2.1.10. 7. Complied 8. Complied 9. Complied 10. Complied 11. Complied 12. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. It appears that cut and fill will not be occurring for the proposed patio. However, as part of the site submittal requirement estimated cut and fill quantities are required to be indicated on the plans so that it is clear to the inspector that no cut in fill is to be taking place. If not cut and fill is taking place indicate the quantity of zero (0) on the plan. Estimated cut and Fill: Cut = 0 and Fill = 0 will suffice. 13. DS Sec.2-02.2.1.A.18: Revise the site plan to call out Pima Street and Alvernon Way as a Major Streets and Routes (MS&R). Provide a note stating that the site plan is in conformance with the MS&R overlay zone criteria. 14. Show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. Please show label dimensioned for both existing and future right-of-ways per D.S. 2-02.2.1.19. Provide letter from Craig as discussed at counter 5/7/09. 15. DS Sec.2-02.2.1.A.19: Label the 11-foot future sidewalk and curb area on the site plan to verify that all improvements are located outside of the future ROW. 16. Complied 17. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 18. Complied 19. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Provide contour interval on plan. 20. Complied 21. Provide the site plan activity number in the lower right hand corner of each sheet per D.S. 2-02.2.1.29. 22. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 23. Acknowledges 24. Complied 25. A floodplain use permit will be required if any work taking place within the identified floodplain limits. 26. Add note: "Depress all landscaped areas 6" maximum for water harvesting". 26. Complied 27. Revise handicap sign to read $532 FINE. 27. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/28/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 05/28/2009 | SUE REEVES | REJECT SHELF | Completed |