Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T08CM02268
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/23/2008 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 09/23/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 23 SEPTEMBER 2008 T08CM02268/THE MEADOWS AT TANQUE VERDE-2ND RESUBMITTAL REVIEWED BY RON BROWN ACCESSIBLE REVIEW-2ND RESUBMITTAL 2006 IBC/ICC 117.1 DENIED: SEE COMMENTS BELOW A. OK B. OK D. OK E. ONE PARKING SPACE PER EACH BUILDING IS TO BE "VAN ACCESSIBLE" AS PER 2006 IBC, CHAPTER 11 AND ICC 117.1, SECTION 502. 1. PLEASE CLARIFY HOW THE FIVE EXTERIOR SPACES ARE "VAN ACCESSIBLE" AND COMPLIES WITH ICC 117.1, SECTIONS 502.2 AND 502.5 REQUIREMENTS INCLUDING WIDTH, AISLES, SIGNAGE, SURFACE SLOPES AND ETC. RESUBMITTAL COMMENT: "VAN ACCESSIBLE" SPACE (TYP) DETAIL: a. DIMENSION WIDTHS FOR "VAN ACCESSIBLE" PARKING SPACES ARE 5' AISLE AND 11' PARKING SPACE OR 8' AISLE AND 8' SPACE AS PER SECTION 502.2. b. SHOW 2% SLOPE MAXIMUM LATERAL SLOPE AS PER SECTION 502.5 c. IS THE TOP PORTION OF THE PARKING AISLE FLUSH IN ELEVATION WITH THE CROSSING ACCESSIBLE ROUTE ADJOINING THE AISLE FOR POSSIBLE ACCESS TO THE ACCESSIBLE ROUTE? d. SHOW THE DIFFERENT SLOPES OF ALL THE CONNECTING 5' CONCRETE ACCESSIBLE ROUTES FROM THE PARKING AISLES TO THE DRIVEWAYS AT THE "VAN ACCESSIBLE" PARKING SPACES COMPILING WITH SECTION 405, SIDE WALK RAMPS. e. THE ACCESSIBLE PARKING SIGN NEEDS TO HAVE A "VAN ACCESSIBLE" SIGN ADDED JUST BELOW THE MAIN SIGN. 2. OK F. OK G. OK H. ADDITIONAL COMMENTS ON NEW REVISIONS TO PLANS 1. SHEET 2 OF 3, ADDED NOTE UPPER LEFT HAND PORTION OF SHEET a. KEY NOTE 4 IS NOT INCLUDED ON THIS SHEET b. PLEASE CLARIFY AND REFERENCE ANSI STANDARDS FOR "VAN ACCESSIBLE" PARALLEL PARKING. END OF REVIEW |
| 10/03/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the following information: a. the location and size of the water meters b. the invert and rim elevation of all manholes c. the locations of the connections to the public sewer Reference: City of Tucson Development Standard No. 2-05.0 2.3 and Section 103.2.3, UPC 2006 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/06/2008 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |