Permit Number: T08CM02268
Parcel: 133420570

Review Status: Completed

Review Details: SITE

Permit Number - T08CM02268
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/09/2008 MARTIN BROWN FIRE REVIEW Approved
07/09/2008 RBROWN1 ADA REVIEW Passed NOT A COT PROJECT
07/09/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 9 JULY 2008
T08CM02268/THE MEADOWS AT TANQUE VERDE
REVIEWED BY RON BROWN

ACCESSIBLE REVIEW
2006 IBC/ICC 117.1

DENIED: SEE COMMENTS BELOW

A. DENOTE GOVERNING ACCESSIBILITY CODE; 2006 IBC, CHAPTER 11 AND ICC 117.1 FOR PRIVATE PROPERTY.
B. SHOW LOCATION OF NEAREST PUBLIC TRANSPORTATION POINT AS PER 2066 IBC, SECTION 1104 AND ICC 117.1, SECTION 402.
D. PROVIDE ACCESSIBLE ROUTE CONNECTION TO PUBLIC R.O.W. FROM EACH BUILDING.
E. ONE PARKING SPACE PER EACH BUILDING IS TO BE "VAN ACCESSIBLE" AS PER 2006 IBC, CHAPTER 11 AND ICC 117.1, SECTION 502.
E. INSURE COMPLIANCE WITH THE INCLUSIVE HOME DESIGN ORDINANCE NUMBER 10463.
F. PROVIDE OCCUPANCY CLASSIFICATION ON COVER SHEET AS PER 2006 IBC, CHAPTER 3.

END OF REVIEW
07/22/2008 HEATHER THRALL ZONING REVIEW Denied TO: Development Services Department, Plans Coordination Office

FROM: Heather Thrall, Senior Planner

PROJECT: T08CM02268, 6649 - 6689 E. Calle Alegria, multi-family
existing plat for condos from 1971, developing site to match plat
commercial site plan, 1st rview

TRANSMITTAL DATE: July 23, 2008

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Per zoning administration letter July 24, 2007, this project is the construction of multi-family structures to fit to the existing plat from 1971. A copy of the plat mentioned in the zoning advisement letter, BK 4158 Page 481-498, was found in the submittal to the zoning administration division and reviewed for compliance with this proposal. PLEASE PROVIDE A COPY OF THAT PLAT IN THE SITE PLAN RESUBMITTAL PACKAGE . Note, several elements of the development were not clarified in the plat nor in the zoning advisement letter, thus staff defaulted to current code requirements. In addition, staff reviewed the project for compliance with the Land Use Code (LUC) and Development Standards (DS) - and for site plan content outlined under DS 2-02. Note that alley access to these units is not in conformance with the LUC, however, it is in conformance with the existing development.

2. Per DS 2-02.2.1.4, regarding location map:
A) please enlarge type size within location map for records - minimum size 12 point
B) please correct adjacent section number in the lower left diagonal corner to read "12"

3. Per DS 2-02.2.1.6, regarding buildings:
A) I see in the general notes the height listed, thank you. Please provide a note stating the units are 2 stories.
B) please note any overhangs and porches
C) please note the number of bedrooms per unit

4. Per DS 2-02.2.1.7, regarding setbacks:
A) Per the plat referenced in comment 1, provide a 35' setback from the north lot line
B) Change notes to reflect this is a developing area for this lot per LUC 3.2.6.5.A
C) Setback required from Calle Serna and Calle Alegria at minimum is the greater of 21' or the height of the exterior building wall, measured from the nearest adjacent travel lane. Note on drawing, list in notes on sheet 1 and keynote travel lane and parking lanes on sheet 2 for both streets.
D) Setback at west lot line is the greater of 10' or 3/4 of the height of the exterior building wall for R-3 to R-3. Call out provided setback and wall height facing west lot line.
E) Will check to ensure setbacks for all buildings met on next review.

5. Per DS 2-02.2.1.8, regarding parking:
A) in the parking calculation, please declare the number of bedrooms for each unit, note parking requirements could increase depending upon the number of bedrooms per unit.
B) per DS 3-05 and LUC 3.3.7.6, tandem parking in multi-family developments is not permitted. Parking must be designed to meet DS 3-05, with striping, back up spurs, minimum PAAL requirements to access the parking, etc.
C) further review comments forthcoming on parking elements - dimension spaces, show back up spurs, Parking Area Access Lanes, wheel stops, handicapped signage, - will be checked on next submittal when re-design is accomplished to have parking required meet DS 3-05 criteria.

6. Per DS 2-02.2.1.9, regarding bike parking:
A) provide detail drawings for both class 1 and class 2 bike parking
B) per DS 2-09.3.2, bike parking access must be separate from pedestrian ways. It appears access to bike parking is via the pedestrian route. Access to bike parking is permitted from vehicular use area - please relocate the bike parking spaces.

7. Per DS 2-02.2.1.11, staff acknowledges the site has traditionally had alley access as primary vehicular access for units, not conforming to LUC 3.2.8. access requirements - and will be allowed to continue with the proposed projects.

8. Per DS 2-02.2.1.12, regarding pedestrian access:
A) per DS 2-08.4.1.A, provide sidewalk to Calle Serna and Calle Alegria
B) per DS 2-08.3.1., provide sidewalk to connect to all units on site
C) please dimension width of sidewalks
D) call out dumpster location and provide pedestrian route to dumpster

9. Per DS 2-02.2.1.20, please ensure all easements are called out, with type and recordation information.

10. Per DS 2-02.2.1.25, please call out any free standing lighting with vertical clearance and base width.

12. Please note, depending upon responses provided, further review comments may be forthcoming. I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951.


HCT C:\planning\site\DSD\T08CM02268 6649 e calle alegria.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
07/25/2008 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. Pedestrian access cannot be located within required landscape border. Dimension landscape borders.

2. In situations where the street landscape border is wider than 10' the width needs to be determined for the purpose of calculating 50% coverage LUC 3.7.2.4 the width is the area between the required screen and property line if no screen is required than the border is measured between the building(s) and the property line. Revise coverage as necessary.

3. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4 .

4. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g.

5. A 10' Interior landscape borders is required as a buffer along the common property lines between adjacent residential land uses and zones.

6. One (1) canopy tree must be provided for every thirty-three (33) linear feet of interior and street landscape borders per LUC 3.7.2.4. Additional trees are required for adjacent residential properties and street landscape border along Camino Serina.

7. A 5' wall is required to screen vehicle use area from residential zoned properties LUC 3.7.2-I

8. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.

9. Additional comments may apply.
07/28/2008 ANDREW CONNOR NPPO REVIEW Approved Exception
08/04/2008 PAUL MACHADO ENGINEERING REVIEW Denied To: Star Consulting DATE: August 4, 2008
5405 E. Placita Hayuco
Tucson, Arizona 85718

SUBJECT: Meadows at Tanque Verde, 6649 E. Calle Alegria
Site plan T08CM002268 (First Review)
T14S, R15E, Section 06

RESUBMITTAL REQUIRED: Site Plan and Hydrology Report.

The Site Plan (SP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. Per all new developments, sidewalks will be required along the frontages of the development.
3. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207.
4. Please provide property description per D.S. 2-02.2.1.3.
5. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
6. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the SP.
7. Sidewalks, curbs and wheelchair ramps are required where applicable per D.S. 3-01.3.0 and installed with "Detectable Warnings" per ADAAG.
8. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
9. Show Site plan number (T08CM02268) on all sheets per D.S. 2-02.2.1.29.
10. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Contact Environmental Services @ 791-5543 x1212, Andy Vera, for approval of curbside pickup and/or for refuse enclosure questions.
11. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
12. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
13. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
14. List the consulting engineer and the owner/developer on the plans with the pertinent information.
15. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
16. A Stormwater pollution prevention plan (SWPPP) is required during Grading plan submittal. See SWPPP requirements listed with grading comments. Contact Paul P. Machado for information at 837-4932.
17. Sidewalks are required as part of new development of all properties. All newsubdivisions and applications for building permits shall provide five (5) foot widesidewalks along the entire length of street frontage, whether public or private, ofthe property in question. The sidewalk requirements also apply to expansions infloor area, site area, or vehicular use area of twenty-five (25) percent or more. Sidewalks are not required in the following circumstances per D.S. 3-01.3.3.A.

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. 5-year threshold retention is required.
3. A Drainage report is required for any site greater than one acre in size or for any site subject to detention requirements…..per S.M.D.D.F.M., chap. II, 2.1.2.
4. The content and format of the Drainage Report should follow S.M.D.D.F.M., chap. II, 2.2.
5. Show the project address or administration address on the cover sheet of the DR.
6. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/6649 E. Calle Alegria_SITE

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2008 CPIERCE1 OUT TO CUSTOMER Completed