Permit Number: T08CM02069
Parcel: 107082480

Address:
701 W ALTURAS ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO

Permit Number - T08CM02069
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/18/2008 HEATHER THRALL ZONING REVIEW Approved
04/18/2008 HEATHER THRALL NPPO REVIEW Passed
06/13/2008 LOREN MAKUS ENGINEERING REVIEW Approved
07/15/2008 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 7-17-08
Activity: T08CM02069
Address: 701 W. Alturas
Applicant: Rosa Valdez

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.
2. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. All plan pages should reference this code or appeal to the Building Official for use of the UBC or UMC.

SECTIONS - DETAILS:
3. The simplified prescribed energy values for ceilings is R=30, N1102.1. Specify the type of insulation that will provide the required R-value in a 5 1/2" cavity (2x6 rafters).
4. Show footing details minimum 12" below undisturbed soil, R319.1 & R403.1.6.

PLUMBING PLAN:
5. Sleeves are required when a gas line passes through concrete, UPC 1211.1.5. Provide gas line layout if the existing gas line is to be relocated, UPC 1217.0 Table 12-8.

MECHANICAL PLAN:
6. Show supply and return ducts with minimum R-8 insulation, R1103.2.1.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
07/29/2008 CPIERCE1 OUT TO CUSTOMER Completed
07/29/2008 SUE REEVES REJECT SHELF Completed