Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM01910
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/06/2008 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T08CM01910 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets (clouded revision notation is not necessary for comment changes). All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007, the 2006 UPC with amendments on 7/10/2007 and effective 1/1/2007 the Inclusive Home Design. All plans should reference these codes. Adopted amendments are found at: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html SECTIONS - DETAILS: 1. Show fiber-cement board or glass mat gypsum backers (rather than water resistant GWB) for tiled walls in tub and shower areas, R702.4.2. Revise (tub/shower plan note and/or interior material note 3 on sheet 4). 2. Show compliance with R806 by providing sufficient attic venting. Provide calculations and show additional venting to supplement that shown on Detail 2/6. PLUMBING PLANS: 1. Provide (3/4") future gas piping between each utility closet and building exterior or submit exemption documentation (Southwest Gas unavailability statement or Building Official appeal), Arizona Statute 30-809. OUTDOOR LIGHTING CODE 1. The product sheet provided shows an adjustable fixture (Fixture "B"). Full cut-off fixtures have no emittance above the nadir (fixtures are completely closed above and to the lowest point of the lamp). Provide a means of permanently configuring the fixture as Full cut-off. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |