Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T08CM01781
Parcel: 137055300

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T08CM01781
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2008 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
07/28/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide upper terminal cleanouts for fixtures P-3, P-6, and FS-1 (in room 104). The size of the cleanouts shall be per table 7-6, UPC 2006 at a minimum but no larger than the size of the pipe onto which it is connected. Reference: Sections 707.4 and 707.11, UPC 2006.
2. Provide the listing information for the vacuum relief valve specified for use on the water heater to show that it is properly installed (e.g. on the cold water inlet to the water heater and with no valves between it and the water heater) per the manufacturer's instructions.
3. Note that the Watts model 775QT-S shown in detail 1/P2.01 is not only an obsolete product according to Watts Regulator, it is not an RPZ backflow preventer.
07/28/2008 CPIERCE1 MECHANICAL-COMMERCIAL REVIEW Denied 1. The submitted calculations do not appear to provide ventilation comparable to that required by Section 403.3, IMC 2006. The space is not a mall, an arcade or a dressing room. Revise the calculations using more appropriate occupancy classifications from Table 403.3 or an engineering analysis. Reference: Sections 403.3 and 403.3.2, IMC 2006.
2. If the restroom exhaust fans are controlled by the restroom light switch, then 100% of the supply air that enters the restroom will be transferred to the space when the lights are turned off. Show how the restroom exhaust complies with Section 403.2.1 (4), IMC 2006.
08/01/2008 RONALD BROWN ZONING HC SITE REVIEW Approved