Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08CM01562
Parcel: 12904157A

Review Status: Completed

Review Details: REVISION - - 1ST

Permit Number - T08CM01562
Review Name: REVISION - - 1ST
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/08/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
10/15/2009 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied The addressing shown on the plans (Buildings 1A, 1B, 2A, 2B, etc) does not correspond to the recorded addresses (Buildings 1, 2, 3, 4, etc.). Revise the plans as required match the records or see Addressing in Pima County to resolve the situation.
10/16/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. The addressing shown on the plans (Buildings 1A, 1B, 2A, 2B, etc) does not correspond to the recorded addresses (Buildings 1, 2, 3, 4, etc.). Revise the plans as required match the records or see Addressing in Pima County to resolve the situation.
2. Revise the riser diagram 2/P1.2 to comply with the requirements of Section 909.1, IPC 2006 (wet venting is restricted to bathroom groups).
3. The scupper design for this building (detail 2/A4.2) shows a 3" dam prior to the overflow. Full flow across the overflow weir is not established with less than 2" of head above the weir. Has the structural design of the roof taken this additional load into account? Reference: Section 1611.1, IBC 2006 and 1107.3, IPC 2006.
10/21/2009 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
11/04/2009 CPIERCE1 OUT TO CUSTOMER Completed
11/04/2009 SUE REEVES REJECT SHELF Completed