Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM01515
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2009 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 1-09-09 Activity: T08CM01515 Address: 2614 N. Flanwill Bl. Applicant: Kelly Hales Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Provide a one-hour fire-rated wall or partition separating the proposed porch in line with the common wall of the duplex, R302.1. SECTION DETAILS: 3. Ref: Detail 1 Sheet 2. Provide a one-hour rated construction detail for walls located with 3 feet of the fire separation line, R302.1. Refer to IBC Table 720.1 for acceptable construction assemblies. 4. Ref: Detail 4 Sheet 4. Justify the ability of the existing 1x8 fascia to sufficiently support the proposed porch framing. PLUMBING PLANS: 1. Relocate gas meter from under porch structure or provide acceptable sleeve alternative for gas piping underground beneath buildings, G2415.11. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/24/2009 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 02/24/2009 | SUE REEVES | REJECT SHELF | Completed |