Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM01503
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/22/2008 | RBROWN1 | ADA | REVIEW | Denied | 22 MAY 2008 T08CM01503/COT CONVENTION CENTER REVIEWED BY RON BROWN ACCESSIBLE REVIEW ADAAG DENIED: SEE COMMENTS BELOW I. SHEET A0.0 A. DENOTE GOVERNING ACCESSIBILITY CODE; ADAAG 1994 EDITION. ACCESSIBILITY COMPLIANCE FOR THIS PROJECT WILL BE REVIEWED SOLELY AS PER ADAAG REQUIREMENTS. II. SHEET A0.1: A. DETAIL 1: USE 3'-0" DIMENSION FOR TISSUE DISPENSER LOCATION, VERTICAL BAR IS NOT ADAAG REQUIREMENT. B. DETAIL 4: AS PER ADAAG, FIGURE 28, THE LAVATORY MAY ENCROACH INTO THE TOILET CLEAR SPACE. C. DETAIL 7: SHOW THE MINIMUM AND MAXIMUM CLEAR SPACE POSITIONING AT THE LAVATORY AS PER ADAAG FIGURE 32. III. SHEET A4.1: A. DETAILS 2, 4 AND 6: SHOULDN'T THE ENTRY DOORS HAVE AN ELECTRONIC OPENING SYSTEM? B. DETAIL 4: DOE THE PAPER TOWEL DISPENSERS MEET ADAAG 4.4, PROTRUDING OBJECTS? C. INSURE ALL LAVATORIES MEET DIMENSIONAL REQUIREMENTS OF DETAIL 7/A0.1. IV. SHEETS A5.1: A. DETAILS 1, 2 AND 3: END TOILET STALLS WITH PARALLEL GRAB BARS DO NOT COMPLY WITH ADAAG, PARAGRAPH 4.22.4. THESE STALLS SHOULD BE MORE LIKE DETAIL 3.A5.2 V. SHEETS A5.2: A. DETAILS 1 AND 2: SHOULDN'T THESE ENTRANCE DOORS HAVE AN ELECTRONIC OPERATIONAL OPENING SYSTEM? B. DETAIL 3: PROVIDE ELECTRONIC OPENING SYSTEM FOR THE WOMEN'S TOILET ROOM. VI. SHEETS A3.0, 3.1 AND 3.2: A. INSURE ALL MODIFIED LAVATORIES HAVE PROPER PIPING INSULATION INSTALLED. VII. SHEETS E7.0: A. WHY NOT STROBES IN THE NORTH WEST TOILET ROOMS? END OF REVIEW |
05/22/2008 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | LETTERING FONTS FOR ALL DRAWINGS TO BE MINIMUM OF 1/8" HIGH OR OBTAIN APPEAL FROM BUILDING OFFICIAL FOR 3/32" HIGH FONTS. APPROVED APPEAL MUST BE SUBMITTED WITH REVIEW DRAWINGS. |
05/23/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
06/09/2008 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
06/13/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
06/13/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
06/13/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
06/19/2008 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
06/20/2008 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
08/01/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |