Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM01435
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 6-08-08 Activity: T08CM01435 Address: 4209 E. Paseo Grande Applicant: Larry Vehnekamp Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. SITE PLAN: 2. The 1996 Pool and Spa code is no longer an adopted standard for the City of Tucson. FOUNDATION PLANS: 3. Provide venting for under-floor areas, 408.1. 4. Specify size of access to under-floor area, 408.4. FLOOR FRAMING: 5. Justify floor beam size for intended load. 6. Clarify joist hanger series specified. STRUCTURAL: 7. Provide roof framing plan. ELEVATIONS: 8. Provide a minimum of 20% of the required ventilation area in the eave vents to qualify for the 1:300 calculation, R806.2. 9. Specify the exterior wall covering on the addition, R703.1. SECTIONS - DETAILS: 10. Specify ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. PLUMBING PLAN: 11. Provide the size of the existing water meter, and the diameter of the water line, UPC Table 6-6. 12. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, UPC 609.10. MECHANICAL PLAN: 13. a Show supply and return ducts with minimum R-8 insulation, R1103.2.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 06/13/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | Material and labor not broken out. In addition Development Services Department - Building evaluation = $56,586.00 too much of a discrepency. Clarification and revised cost estimate required. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/17/2008 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 06/17/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 06/17/2008 | GERARDO BONILLA | REJECT SHELF | Completed |