Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T08CM01427
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/22/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Beverages & More T08OT01427 Site Plan (1st Review) TRANSMITTAL DATE: October 21, 2008 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). 2. D.S. 2-02.2.1.A The site plan is drawn at a standard engineering scale no larger than l" = 60' on a sheet(s) no larger than 30" by 42" (24" by 36" recommended). 3. D.S. 2-02.2.1.A.4 The project location map shows the building on the west side of Oracle Road, please clarify. 4. D.S. 2-02.2.1.A.5 Provide lot lines, dimensions and bearings on the plan. 5. D.S. 2-02.2.1.A.6 For all angled parking on site provide the following: A - Parking Angle, C - Space Depth & E - Curb Length, see LUC Section 3.3.7.2 for clarification. 6. D.S. 2-02.2.1.A.6 There is a proposed handicapped parking space located at the east end of the existing building that it does not appear that the proposed access aisle meets the minimum width requirements, please clarify. Also so the accessible route that provides access to the building from this proposed space. 7. D.S. 2-02.2.1.A.6 The wheel stops shown for the angled parking along the south side of the building and for the southern parking spaces are not shown correctly. 8. D.S. 2-02.2.1.A.6 There are three (3) vehicle parking spaces along the west end of the building that encroach in to the minimum four (4) foot width of the sidewalk, revise plan to maintain four (4) foot clear. 9. D.S. 2-02.2.1.A.12 Near the southwest corner of what appears to be a cart corral a four (4) sidewalk, physically separated from the vehicle use area is required. 10. Remove the reference to the "(N) DELIVERY AREA", located near the northwest corner of the building, as this area does not meet the requirements of LUC Section 3.4.4. 11. Remove the reference to the "12'x55' LOADING ZONE; ADJACENT TENANT" and the striped area from the plan. 12. The dimension strings of 4'-0", along the west side of what appears to be a cart corral, do not meet the requirements of twelve (.12) text, enlarge the dimensions. 13. Additional comments may be forth coming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t08cm01427 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents. |
| 10/22/2008 | RBROWN1 | ADA | REVIEW | Passed | NOT A COT PROJECT |
| 10/22/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 22 OCTOBER 2008 T08CM01427/BEVMO ON ORACLE REVIEWED BY RON BROWN ACCESSIBLE REVIEW 2006 IBC/ICC 117.1 DENIED: SEE COMMENTS BELOW I. NEITHER ACCESSIBLE PARKING PLAN WORK, REDESIGN A. WEST END GROUPED ACCESSIBLE PARKING 1. GROUPED SPACES DO NOT MEET ICC/ANSI 117.1, SECTION 502.4.3: LENGTH: ACCESS AISLES SHALL EXTEND THE FULL LENGTH OF THE ACCESSIBLE PARKING SPACE. 2. PARKING AREA SLOPES MUST NOT EXCEED 2% EACH WAY, ICC/ANSI 117.1, SECTION 502.5 3. IDENTIFY A "VAN ACCESSIBLE SPACE AND MAKE ACCESS AISLE 8' WIDE 4. WHERE VEHICLE PAVING IS FLUSH WITH ACCESSIBLE ROUTE, A PHYSICAL BARRIER MUST BE IN PLACE BETWEEN THE TWO EXCEPT AT THE ACCESS AISLES. THIS IS GENERALLY A 6" SURFACE MOUNTED CURB. REFERENCE ZONING COMMENTS. 5. ACCESSIBLE ROUTE IN FRONT OF ACCESSIBLE PARKING IS TO BE 4' WIDE MINIMUM. REFERENCE ZONING COMMENTS. 6. A DETECTABLE WARNING PAD IS NOT REQUIRED BY CODE TO BE ON THE RAMP UP TO THE ACCESSIBLE ENTRY. B. EAST END ACCESSIBLE PARKING SPACE: 1. DOES NOT HAVE COMPLIANT SIZED AISLE AS PER ICC/ANSI 502.4.3 2. DOES NOT HAVE AN ACCESSIBLE ROUTE TO FRONT ENTRANCE. 3. CANNOT BE USED FOR ADJACENT TENANT BECAUSE VACANT WAREHOUSE IS TO REMAIN A WAREHOUSE NOT A TENANT. PLEASE REFERENCE AGREEMENT WITH CHIEF INSPECTOR LEERAY HANLEY. END OF REVIEW |
| 10/23/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | Existing development on the site is subject to the zoning regulations in effect at the time the existing development received zoning approval. Ensure that all Zoning comments and concerns are addressed. |
| 10/23/2008 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 10/23/2008 | JASON GREEN | ENGINEERING | REVIEW | Denied | Refer to Handicap and Zoning comments for parking requirments and handicap requirements. Verify all PAAL dimensions (2-way and 1-way). Provide property lines on site plan. |
| 10/23/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Revise the site drawing to include the following information: a. the location and size of the water meter b. the location of the main water lines and fire hydrants c. the location and size of the public sanitary sewer and d. the location and rim elevation of the next upstream manhole. e. the first floor elevation Reference City of Tucson Development Standard No. 2-05.0 2.3 and Section 103.2.3, UPC 2006. |
| 10/24/2008 | DAVE MANN | FIRE | REVIEW | Approved |