Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM01202
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/22/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 7-24-08 Activity: T08CM01202 Address: 2154 S Mcfee Ave Applicant: Jesus Romo Sandate Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FLOOR PLANS: 2. Show the location of attic access min. 22"x30", R807. STRUCTURAL PLANS: 3. Specify the size and spacing of rafters or provide truss calculations dated and wet-sealed by an engineer who is registered in Arizona, R801.2 ELEVATIONS: 4. Specify roof slope and roofing type, grade of materials, and method of installation, R905. SECTIONS - DETAILS: 5. Specify wall and ceiling covering. Note: Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. PLUMBING PLAN: 6. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, UPC 609.10. MECHANICAL PLAN: 7. Show supply and return ducts with minimum R-8 insulation, R1103.2.1. 8. Gas appliances shall comply with UPC combustion air requirements or Chapter 17, 2006 IRC. Show compliance for all gas-fired appliances. Confined spaces require a minimum of two 100 SQ. IN. openings, M1702.2. ELECTRICAL PLAN: 9. Specify that all smoke detectors shall be interconnected with a power source from the building wiring, and shall be equipped with battery backup, R313. 10. Bedroom outlets shall be arc-fault protected (receptacles, lights, and smoke detectors), E3802.12. OUTDOOR LIGHTING CODE 11. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style). Note: Flood-style lighting is not considered fully shielded. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/05/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 08/05/2008 | SUE REEVES | REJECT SHELF | Completed |