Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T08CM01171
Parcel: 129041490

Review Status: Completed

Review Details: RESUBMITTAL - SITE

Permit Number - T08CM01171
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/17/2008 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Casitas on Broadway
T08CM01171
Site Plan (2nd Review)

TRANSMITTAL DATE: July 17, 2008

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance.

2. Zoning acknowledges your response but based on LUC Section 3.2.6.5.B Table 3.2.6.I the most restrictive setback would be measured from the back of curb and this dimension is not shown. D.S. 2-02.2.1.A.7 The setback to Plumer Avenue is not shown correctly. This setback is based on LUC Section 3.2.6.5.B Table 3.2.6.I ADT of 1000 or greater measured to the back of curb.

3. D.S. 2-02.2.1.A.9 Zoning acknowledges that this comment was not made on the last review. Per D.S. 2-09.5.1.B a minimum of thirty-six (36) inches will be provided between a perpendicular wall of other obstruction. This said it appears that there is a wall perpendicular wall at the south end of the proposed bicycle parking, revise the detail to show the correct dimension.

4. Zoning is will to provide an over-the-counter review once the above comments have been addressed. Please call or email to schedule an appointment for the above review.


If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t08cm01171-2nd

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
07/23/2008 RBROWN1 ADA REVIEW Approved
07/29/2008 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. On streets designated as Major Streets and Routes (MS&R), the 10' street landscape border is measured from the MS&R right-of-way line as determined by Sec. 2.8.3.4. The entire street landscape border along Broadway Blvd. is not 10' as measured from future ROW line, revise plans as necessary.

2. A street landscape border per LUC 3.7.2.4, is an area running the full length of the street property line bounding the site except for points of ingress-egress. Pedestrian access on Plumer Ave. cannot be located within required street landscape border. Revise site and landscape plan as necessary. Additionally where Olsen Ave. ends street landscape border is required.

3. All landscape areas will be depressed to accept water flow from roofs, PAAL, and parking areas. Show by detail or spot elevations how landscape areas will accommodate water harvesting.

4. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.

5. Additional comments may apply
08/06/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: August 11, 2008
SUBJECT: Site Plan
TO: MPE
LOCATION: 2121 E Broadway, T14S, R14E, Section 8, Ward 6
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T08CM01171 (Second Review)


RESUBMITTAL REQUIRED: Site Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments along with the corrected copies of the site plan.

Site Plan:


1. Complied
2. Complied
3. Complied
4. Complied
5. Complied
6. Complied
7. Complied
8. Complied
9. Complied
10. Label egress and ingress and label parking area access lanes PAAL(s) per D.S. 2-02.2.1.11.
11. DS Sec.2-02.2.1.A.11 & DS Sec.3-01.3.2.C: Depict and label 25-feet radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrance along Broadway Blvd. The curbs should be constructed at the edge of pavement and entirely on the subject property, which must also be depicted on the site plan.
12. Per City of Tucson, Transportation Access Management Guidelines, Guideline 5.4.1 states entrance and exit drives crossing arterial and collectors are limited to two per three hundred feet of frontage along any major roadway. The nearest pavement edges spaced at least eighty feet apart. Guideline 5.4.1 states a minimum of one hundred and fifty feet, measured at curbline, shall separate the nearest pavement edge of any entrance or exit driveway and the curbline to any signalized intersection with arterial and collector roadways. For questions in regard to Transportation Management Guidelines please contact Jose Ortiz, Civil Engineer, for questions. For comments 11 and 12 provide approval from Transportation department.
13. Complied
14. Complied
15. Fully dimensioned maneuvering area(s) for loading zones per D.S. 2-02.2.1.14. Verify manueverability - utiliIzing template it does not appear to be working.
16. Show the limits of the 100-year floodplain per D.S. 2-02.2.1.15.
17. See comment #16
18. Complied
19. Complied
20. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Plumer Avenue.
21. DS Sec.2-02.2.1.A.19: Label the 11-foot future sidewalk and curb area on the site plan to verify that all improvements are located outside of the future ROW. Response acknowledged - provide letter or email from Vincent to me (Bianca Ramirez) for approval.
22. Verify that all easements of record have been graphically shown on the plan together with recording docket and page per DS 2-02.2.1.20. Provide recordation informtation for 15' Access Easement called out within SECTION A.
23. Complied
24. Complied
25. Complied
26. Complied
27. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
28. Complied
29. DS Sec.2-02.2.1.A.16: Provide drainage arrows and locations of all concentration points. Specifically show roof down spout locations from existing and proposed buildings at pedestrian circulation areas. Indicate drainage symbol in legend to identify drainage arrows.rian sidewalk is required. Detail D does not reflect City of Tucson Detail 204. Detail resembles City of Tucson detail 205.5. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk.
30. Complied
31. A Stormwater pollution prevention plan (SWPPP) is required during Grading plan submittal. See SWPPP requirements.
32. "A grading permit and Stormwater Pollution Prevention Plans (SWPPP's) may be will be required for this project. Submit 3 sets of grading and SWPPP's with text, upon completion and submittal of a grading permit application. A grading permit may not be issued prior to site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans".
33. Provide detail for wall opening(s) and provide spacing.
34. Verify that keynote 33 is referencing correct detail reference.
35. Additional comments may be forthcoming.

DRAINAGE STATEMENT:

1. Correct section township and range.
2. Provide documentation HEC RAS Model being referenced to Appendix F - nothing found within Appendex F.
3. Map provided in Appendix B is indicating Soil Type D.
4. Provide calcuation in section G. Provide discussion of how the openings are to be provided.
5. Per drainage report provide location of floor drains and provide detail.
6. Additional comments may be forthcoming.
If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax