Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-COMMERCIAL
Permit Number - T08CM01148
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/14/2008 | DROBEY1 | FIRE | REVIEW | Needs Review | |
| 05/14/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | May 14, 2008 FLOODPLAIN USE PERMIT # T08OT01150 PROJECT ADDRESS: 8750 E Cooper Street APPLICANT'S NAME: SbbL Architecture and Planning - Caroyln PROPERTY OWNER: Greg Shear This parcel is impacted by a determined City of Tucson 100-year floodplain. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: 8750 E Cooper Street, Tucson, AZ 85710, CENTENNIAL PARK NO 3 THAT PART OF BLK 3 L YG NELY OF DRAINAGEWAY EASEMENT In a portion of Township 14 South, Range 15 East, Section 15, for the construction of carport canopies for apartment complex. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) This parcel is impacted by a City of Tucson 100-year floodplain. Therefore, the proposed development is subject to special requirements: A) The canopies are to be built in a manner to prevent flotation, collapse and lateral movement. B) Ramada is to remain open to flow - any future proposal to enclose or to modify from existing plan will require engineering review. C) No Electrical is to service canopies. 3) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT01150 FOR INFORMATION PLEASE CALL 791-5550." 4) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 5) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 6) See the associated activity T08CM01148. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 5 Day: 14 Year: 2009 APPLICANT: SbbL Architecture & Planning / Carolyn ADDRESS: 1001 N Alvernon #105, Tucson, AZ 85711 PHONE: (520) 403-5959 OWNER: Greg Shear ADDRESS: 74478 Highway 111 #232, Palm Desert, CA 92260 PHONE: (520) 403-5959 (Carolyn) SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 05/14/2008 | DROBEY1 | ZONING | REVIEW | Needs Review | |
| 06/03/2008 | WILDAN | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Approved | |
| 06/03/2008 | CPIERCE1 | 3RD PARTY REVIEW-COMMERCIAL | AT 3RD PARTY OFFICE | Completed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/03/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |