Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM01096
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/07/2008 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
04/07/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
04/07/2008 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
04/07/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
04/07/2008 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
04/07/2008 | GERRY KOZIOL | WWM | REVIEW | Approved | |
04/07/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The specified lavatory faucets are designed for a flow rate of 2.2 GPM. According to ARS Title 45, Chapter 1, Article 12, the maximum flow rate for lavatory faucets shall be no more than an average of one-half gallon of water per minute at a pressure of eighty PSI or they shall be equipped with a mechanism that causes the faucet to close automatically after delivering no more than one-fourth gallon of water. Reference: Section 402.1, UPC 2003, as amended by the State of Arizona. 2. Show how the temperature of the hot water supply to the public lavatories is controlled to a maximum temperature of 110 degrees Fahrenheit. Reference: Section 413.1, UPC 2006 and Section 504.3, IECC 2006. |
04/07/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | |
04/07/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
05/05/2008 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |