Permit Number: T08CM01080
Parcel: 134160740

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T08CM01080
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/16/2008 HENRY DURAZO BUILDING-RESIDENTIAL REVIEW Denied 1-Note footing size @ new post for Glu-Lam beams. 2.-Detailed connection required post to beam. 3.-Why the rire wall? Is thier a difference in elevation in Den and Living room slab? See section and clarify. 4.-How is attic access provided in laundry room? 5.- Complete all detailed connections,show positive connections thru-out. 6.Prefab truss design required. 7.-Submit engineered design for rastra construction,or detailed ICBO approved drawing covering all construction. 8.-Complete water distribution plan required, PTR line missing 9.-Clarify why 20x8 duct is being attached to 8x8 duct? Have qualified mechanical person advise on design.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/29/2008 CPIERCE1 OUT TO CUSTOMER Completed
05/29/2008 SHANAE POWELL REJECT SHELF Completed