Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T08CM01044
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/19/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: November 19, 2008 SUBJECT: Site plan with Parking - Demolition TO: Intertech LOCATION: 2902 N Flowing Wells, T14S, R14E, Section 19, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM01044 (Fourth Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Include a response letter to the comments along with the corrected copies of the site plan. Please verify that all text on the submitted site plan is a minimum of 0.12 point font. Recently the FINE for handicap signs has changed. Please change all handicap signs to read $532 FINE. Site Plan: 1. Complied 2. Complied 3. Complied 4. DS Sec.2-02.2.1.A.11 & DS Sec.3-01.3.2.C: Depict and label 25-feet radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrance along Flowing Wells Road. The curbs should be constructed at the edge of pavement and entirely on the subject property, which must also be depicted on the site plan. For exception or questions in regard to Transportation Management Guidelines please contact Jose Ortiz, Civil Engineer with the Trasportation Department. Comment acknowledged, please provide approval from the Transportation Department. Engineering Reponse: Please label the 25' Radaii on site plan. 5. Indicate curb returns for MS&R and call out radius on plans. Comment acknowledged, please provide approval from the Transportation Department. Engineering Reponse: Please label the 25' Radaii on site plan.. 6. See Zoning comments. 7. Complied 8. See Zoning comments. . 9. Complied 10. Complied 11. Downspouts shown. Show direction of existing roof drainage. 12. Complied 13. Complied 14. Complied 15. Information not available. Complied. 16. Complied 17. Complied 18. Complied 19. Complied 20. Complied 21. Complied 22. Complied 23. DS Sec.2-02.2.1.A.32: fully dimension trash enclosure on site plan and provide a detail with dimensions for refuse container on the site plan, the enclosure must have a minimum inside clear dimension of 10 feet by 10 feet between steel bollards that are required between the container and the enclosure's rear and sidewalk. Refer to attached detail DS Sec.6-01.0 for specifications and requirements. Comment acknowledged, provide detail of trash enclosre - see attached trash enclosure detail for example of detail. Include dimensions within detail. Engineering Reponse: Full - code compliance required that the trash enclosure meets the minimum trash enclosure requirements. For relief from this requirement approval from the City of Tucson Environmental Department will be required. Provide approval and email from Environmental Services for approval of request. 24. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 25. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the gradebreak at the driveway, if applicable. Comment acknowledged, provide cross section refered to on the landscape plan and provide on the site plan. Engineering Reponse: Unable to located the cross section on site plan. Please verify that it was placed on plans. If I missed please indicate where it can be found on the plans (ie sheet). 26. Complied 27. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Comment acknowledged, provide note on the site plan. Engineering Reponse: Unable to approve request from relief from requirement. Provide approval from the City of Tucson Landsape Department and have approval complete as well as email sent to me stating that request will be granted. 28. Complied 29. Complied 30. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 11/21/2008 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 11/21/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/01/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 12/01/2008 | SUE REEVES | REJECT SHELF | Completed |