Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T08CM01044
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2008 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | 1. The Pima County Assessor's records show that the site is made up of two separate parcels, which are required to be combined. An Assessor's tax combo form and a lot combination covenant must be completed prior to site plan approval. Provide copies and recordation information as necessary. These forms are attached to the plan roll. 2. A minimum 2-foot shy space is required between a PAAL and any wall, screen or other obstruction provided pedestrian activity is directed to another location per DS 3-05.2.2.B.3. In addition, a 5-foot pedestrian refuge area is required adjacent to the building per DS 3-05.2.2.B.1. Revise the plan accordingly to show the required pedestrian refuge area and provide required parking in a different location. Response comments cite IBC exceptions but these are City of Tucson requirements. 3. The parallel parking spaces in front of the building may not be placed in this area without the minimum required PAAL width adjacent. All maneuvering for parking must be done on site, not on adjacent sites or within the MS&R right-of-way. Revise location of parking spaces. LUC 3.3.7.5 4. Pedestrian circulation must be provided to the building and at least one sidewalk must be provided from the street on which the project has frontage. Sidewalks must connect all areas of the development. DS 2-08.4.1 5. Provide permitting information for the additions and covered storage areas which have been added to the building since the last approved plan. If these additions have not been approved a building permit application must be submitted. 6. Class 2 bicycle parking facilities should be clearly visible from adjacent sidewalks, drives and main entrances per DS 2-09.4.4 7. Class 2 bicycle parking facilities will be located no more than 50 feet from the main building entrances and will be located along the front side of buildings as well as along other sides of the building that have entrances. DS 2-09.4.1 8. Dimension the MS&R future right-of-way and future sight visibility triangles on the site plan. DS 2-02.1.A.10 & .19 |
| 07/29/2008 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 07/29/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1. Landscaping requirements apply to expansion of existing development as follows: On sites where the gross floor area of the existing building(s) is more than ten thousand (10,000) square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows: If the expansion is 25% or greater or if expansions as of February 15, 1991 cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the requirements of this Division apply to the entire site per LUC 3.7.1.2.B. Previous approved plans from city records label the proposed parking lot area as a storage yard. The expansion of vehicular use area (or parking lot expansion) proposed requires full code compliance for the site. 2. The last approved site plan submitted does not show the additions and covered storage areas. Provide permitting information for these additions. If they have not yet been permitted, they must be included as part of this application. 3. Dimension the width of the tree planter area along the south property line. A minimum width of 4 feet of unpaved area is required for the planter area. LUC 3.7.2.3.A.1.c, DS 2-07.2.2.A.2.e 4. A 10-foot street landscape border with a 30-inch screen is required along Flowing Wells Road per LUC Table 3.7.2-I. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by LUC 2.8.3.4. Indicate required landscape border and screening on the landscape plan. 5. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4 6. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g 7. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border or fraction thereof per LUC 3.7.2.4. 8. A 30" continuous screen along MS&R street frontages, except at vehicle and pedestrian access points, must be provided per LUC Table 3.7.2-I |
| 08/11/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 08/18/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: August 19, 2008 SUBJECT: Site plan with Parking - Demolition TO: Intertech LOCATION: 2902 N Flowing Wells, T14S, R14E, Section 19, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM01044 (Second Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Include a response letter to the comments along with the corrected copies of the site plan. Site Plan: 1. Complied 2. Revise and label existing and future sight visibility triangles per D.S. 2-02.2.1.10. Even though the future ROW goes into the existing building, please provide the information as reaquested. 3. Please label all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 4. DS Sec.2-02.2.1.A.11 & DS Sec.3-01.3.2.C: Depict and label 25-feet radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrance along Flowing Wells Road. The curbs should be constructed at the edge of pavement and entirely on the subject property, which must also be depicted on the site plan. For exception or questions in regard to Transportation Management Guidelines please contact Jose Ortiz, Civil Engineer with the Trasportation Department. Comment acknowledged, please provide approval from the Transportation Department. 5. Indicate curb returns for MS&R and call out radius on plans. Comment acknowledged, please provide approval from the Transportation Department. 6. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. Comment acknowledged provide pedestrian circulation must be provided to the building and at least one sidewalk must be provided from the street on which the project has frontage. Sidewalks must connect all areas of the development. Please revise accordingly per DS 2-08.4.1 7. Barriers need(s) to be located between sidewalk and parking space with either wheel barriers or curb. Comment acknowledged - indicate bollards on site plan and dimensions spacing for further review. 8. See comment #6 9. Show the limits of the 100-year floodplain and water surface elevation(s) on the site plan per D.S. 2-02.2.1.15. Comment acknowledged - identified 100-year floodplain does not match maps. Please revise accordingly - provide note on site plan that reads: Parcel is 100% within City of Tucson identified 100-year floodplain. 10. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. Comment acknowledged, show existing drainage patterns and indicate using drainage arrows. Add drainage symbol in legend. 11. DS Sec.2.02.2.1.A.16: Provide drainage arrows and locations of all concentration points. Specifically show roof drainage. 12. Complied 13. Dimension and label existing and future right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. Comment acknowledged, dimension future ROW, even if it goes through the existing building it should be identified on the site plan. 14. Complied 15. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Flowing Wells Road. Comment acknowledged, provide recordation information by either locating on title report of getting a copy from the assessors record. In addition, please indicate whether road is private or public. 16. Complied 17. Complied 18. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 19. Provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Provide contour interval on plan below the north arrow and scale. Comment acknowledged, provide contour interval on the plan below the north arrow and the scale. 20. Complied 21. Show site plan activity number on each sheet in the lower right hand corner of all sheets per D.S. 2-02.2.1.29. Comment acknowledged, call out Site Plan Activity #T08CM01044 and Floodplain Use Permit #T08OT00750. 22. Complied 23. DS Sec.2-02.2.1.A.32: fully dimension trash enclosure on site plan and provide a detail with dimensions for refuse container on the site plan, the enclosure must have a minimum inside clear dimension of 10 feet by 10 feet between steel bollards that are required between the container and the enclosure's rear and sidewalk. Refer to attached detail DS Sec.6-01.0 for specifications and requirements. Comment acknowledged, provide detail of trash enclosre - see attached trash enclosure detail for example of detail. Include dimensions within detail. 24. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 25. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the gradebreak at the driveway, if applicable. Comment acknowledged, provide cross section refered to on the landscape plan and provide on the site plan. 26. List the consulting engineer and the owner/developer on the plans with the pertinent information. Comment acknowledged, please include all pertinent information which includes, name, address, phone number and web address if one exists. 27. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Comment acknowledged, provide note on the site plan. 28. Indicate all symbols on plans and reference in legend. Also reference all details and site information for easy reference. Comment acknowledged, provide drainage arrows. 29. Complied 30. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |