Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T08CM01044
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/08/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 8 MAY 2008 T08CM01044/DESTECH SITE PLAN REVIEWED BY RON BROWN ACCESSIBLE REVIEW 2006 IBC/ANSI-117.1 DENIED: SEE COMMENTS BELOW 1. DENOTE ACCESSIBILITY COMPLIANCE TO 2006 IBC/ICC 117.1 2. PROVIDE AND IDENTIFY ACCESSIBLE ROUTE THROUGHOUT SITE TO ALL BUILDING ENTRANCES AND EXITS AND PARKING FACILITIES AND TO NEAREST PUBLIC TRANSPORATION POINT AS PER 2006 IBS SECTION 1104 AND ICC 117.1 SECTION 402. A. SHOW LOCATION OF NEAREST PUBLIC TRANSPORTATION DROP OFF POINT. B. WIDTH OF ACCESSIBLE ROUTES TO BE MINIMUM OF 4' WIDE. C. PROVIDE SPOT GRADES TO SHOW SLOPE COMPLIANCE WITH 2006 IBC SECTION 1010 AND ICC 117.1 SECTIONS 405 AND 406. 3. PROVIDE ANY AND ALL REQUIRED CURB RAMPS, SIDE WALK RAMPS AND MARKED CROSSINGS AND COMPLY WITH 2006 IBC, ICC 117.1, SECTION 405 AND 406. PROVIDE DETECTABLE WARNINGS AS REQUIRED. 4. VERIFY THAT ALL BUILDING ENTRANCES ARE ACCESSIBLE AS PER 2006 IBC SECTION 1105 AND ICC 117.1, SECTIONS 302 AND 303. 5. ACCESSIBLE PARKING SPACES SHOWN IN FRONT OF BUILDING ARE NON COMPLIANT; NO ACCESS ISLES PROVIDED AS PER ICC SECTION 502.4, RELOCATE. END OF REVIEW |
| 05/08/2008 | RBROWN1 | ADA | REVIEW | Passed | NOT A COT PROJECT, ADAAG NOT APPLICABLE |
| 05/14/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1. Provide a copy of the last approved site plan and landscape plan wtih the next submittal. The site plan submitted does not show the additions and covered storage areas. Provide permitting information for these additions. 2. The site plan must be accompanied by a landscape plan with information specified in Development Standard 2-07.0. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. The review will continue when documents are included with re-submittal. 3. The new parking area proposed along the south property line must meet code. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a 4. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. 5. Both the proper and common name of each type of plant material must be listed. 6. Indicate material and areas of inert ground cover. All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Indicate treatment for landscaped areas. 7. The parking and loading areas must be screened from the street and a 10-foot street landscape border is required along Flowing Wells Road. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by LUC 2.8.3.4. Indicate required landscape border and screening on the landscape plan. 8. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4 9. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g 10. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border or fraction thereof per LUC 3.7.2.4. 11. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I 12. Further comments may apply once a landscape plan is submitted. |
| 05/14/2008 | PETER MCLAUGHLIN | NPPO | REVIEW | Denied | Submit NPPO plan or, if applicable, an application for exception. Include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property per DS 2-15.2.0.C. |
| 05/15/2008 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | 1. A minimum 24-foot wide PAAL is required for 2-way traffic along with a 5-foot pedestrian refuge area adjacent to the building. The loading zone location does not allow enough distance for two way traffic. Revise the plan to meet code, dimension the full 2-way PAAL width and the width of the pedestrian refuge area. LUC 3.3.7.2.A, DS 3-05.2.1.C.1, DS 3-05.2.2.B.1 2. The parking calculation is incorrect for the manufacturing use, which requires 1 vehicle space per 500 square feet of gross floor area. Revise calculation accordingly. LUC 3.3.4 3. Indicate the angle of the diagonal spaces, which must meet the requirements of LUC Table 3.3.7-I. 4. Revise the length of the parallel parking spaces in front of the building to be 23 feet as required per DS 3-05.2.1.B.2. These spaces may not be placed in this area without the minimum required PAAL width. Also, handicap spaces require an adjacent access aisle per ANSI. 5. Provide permitting information for the additions and covered storage areas which have been added to the building since the last approved plan. If these additions have not been approved a building permit application must be submitted. Provide a percent building area expansion calculation on the site plan. 6. The last approved site plan indicates that the site was previously part of the parcel to the south. Provide a copy of aproved lot split documents. 7. The gate at the entrance drive must remain open during buisiness hours. Provide a note on the plan so stating. 8. It appears on aerial photos that most of the outdoor area is used for storage. If this is still the case label all outdoor storage areas on the site plan. 9. Indicate the location of any existing or proposed freestanding signage on the site plan. DS 10. Provide a fully dimensioned bicycle parking detail showing a 6-foot length of space, 30-inches clear along the side of each space and a 5-foot area adjacent to the front or rear of each space which is clearance to allow for maneuvering of bicycles into the spaces. DS 2-09.5.1 & .5.2 11. Class 2 bicycle parking facilities should be clearly visible from adjacent sidewalks, drives and main entrances per DS 2-09.4.4 12. Class 2 bicycle parking facilities will be located no more than 50 feet from the main building entrances and will be located along the front side of buildings as well as along other sides of the building that have entrances. DS 2-09.4.1 |
| 06/06/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 06/23/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: June 24, 2008 SUBJECT: Site plan with Parking - Demolition TO: Intertech LOCATION: 2902 N Flowing Wells, T14S, R14E, Section 19, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM01044 (First Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Include a response letter to the comments along with the corrected copies of the site plan. Site Plan: 1. Please provide north arrow for location map per D.S. 2-02.2.1.4. 2. Revise and label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 3. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 4. DS Sec.2-02.2.1.A.11 & DS Sec.3-01.3.2.C: Depict and label 25-feet radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrance along Flowing Wells Road. The curbs should be constructed at the edge of pavement and entirely on the subject property, which must also be depicted on the site plan. For exception or questions in regard to Transportation Management Guidelines please contact Jose Ortiz, Civil Engineer with the Trasportation Department. 5. Indicate curb returns for MS&R and call out radius on plans. 6. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 7. Barriers need(s) to be located between sidewalk and parking space with either wheel barriers or curb. Looking north going west there is a landscape area with no warning address by adding curb or explain. 8. DS Sec.2-02.2.1.A.12: Revise the site plan to show the required pedestrian circulation path that is required from the proposed buildings to the required pedestrian circulation path located along Fort Flowing Wells Road.. 9. Show the limits of the 100-year floodplain and water surface elevation(s) on the site plan per D.S. 2-02.2.1.15. 10. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 11. DS Sec.2.02.2.1.A.16: Provide drainage arrows and locations of all concentration points. Specifically show roof down spout locations proposed buildings at pedestrian circulation areas. A detail for the dimension of the proposed scuppers that are used for collecting onsite roof drainage at all pedestrian sidewalk is required, refer to City of Tucson details. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk. 12. List estimated cut & fill quantities per D.S. 2-02.2.1.17. If cut and fill will not be occurring for the demolition. As part of the site submittal requirement estimated cut and fill quantities are required to be indicated on the plans so that it is clear to the inspector that no cut in fill is to be taking place. If not cut and fill is taking place indicate the quantity of zero (0) on the plan. Estimated cut and Fill: Cut = 0 and Fill = 0 will suffice. 13. Dimension and label existing and future right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 14. DS Sec.2-02.2.1.A.18: Revise the site plan to call out Flowing Wells Road as a Major Streets and Routes (MS&R). Provide a note stating that the site plan is in conformance with the MS&R overlay zone criteria. 15. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Flowing Wells Road. 16. Verify that all easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 17. DS Sec.2-02.2.1.A.20: Provide on the site plan all easements for existing and proposed utilities (water, gas, electric) and public/private sewer lines. The easements must be shown graphically on the plan together with recording docket and page reference. Reference all easements to detail and/or notes. 18. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 19. Provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Provide contour interval on plan below the north arrow and scale. 20. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27. 21. Show site plan activity number on each sheet in the lower right hand corner of all sheets per D.S. 2-02.2.1.29. 22. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. 23. DS Sec.2-02.2.1.A.32: fully dimension trash enclosure on site plan and provide a detail with dimensions for refuse container on the site plan, the enclosure must have a minimum inside clear dimension of 10 feet by 10 feet between steel bollards that are required between the container and the enclosure's rear and sidewalk. Refer to attached detail DS Sec.6-01.0 for specifications and requirements. If curbside pickup a letter of approval will be required from COT Environmental Services and a Development Standard Modification Request (DSMR) may be required prior to site plan approval. 24. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 25. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the gradebreak at the driveway, if applicable. 26. List the consulting engineer and the owner/developer on the plans with the pertinent information. 27. Add note: "Depress all landscaped areas 6" maximum for water harvesting". 28. Indicate all symbols on plans and reference in legend. Also reference all details and site information for easy reference. 29. DS Sec.2-02.2.1.A.8: Provide wheel stop curbing for parking spaces. Wheel stop barriers must be used at all parking spaces to prevent encroachment into pedestrian circulation areas. If the existing sidewalk is raised, indicate on site plan. 30. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/08/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 07/08/2008 | SUE REEVES | REJECT SHELF | Completed |