Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T08CM00957
Parcel: 12902110B

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T08CM00957
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/31/2008 ANDREW CONNOR NPPO REVIEW Denied Submit NPP plan or Application for Exception per DS 2-15.0 & LUC 3.8.4; include with application acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property per DS 2-15.2.0.C.
04/14/2008 GERRY KOZIOL WWM REVIEW Approved
04/17/2008 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T08CM00957

4/20/08 3020 E. ARROYO CHICO

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


SITE PLAN:

1. PLEASE INDICATE THE ROUTE OF THE SEWER LINE.

2. PLEASE CHECK THE "UTILITY RESOURCES".

3. INDICATE THE ROUTE REQUIRED BY THE INCLUSIVE HOME DESIGN.

FOUNDATION PLANS:

1. PLEASE SPECIFY THE DETAILS.

2. INCLUDE THE INCLUSIVE HOME DESIGN IN ELEVATION CHANGES.

FLOOR PLANS:

1. MSTR. BDRM.:
THE VERTICAL OPENING OF A 3040 SH IS LESS THAN 24". THE HORIZONTAL RAIL REDUCES IT. R310.1.2
THE HORIZONTAL OPENING OF A 6040 XOX IS LESS THAN 20". R310.1.3

2. PLEASE JUSTIFY THE 12" DEEP HEARTH. FIGURE 1001.1 DIMENSIONS APPLY ALSO TO PRE-FAB FIREPLACES. UNLESS THE LISTING SAYS OTHERWISE.


3. IDENTIFY CEILING HEIGHTS IN ALL AREAS ON FLOOR PLAN OR CROSS SECTION..

STRUCTURAL PLANS:

1. PROVIDE MANUFACTURER'S DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA. TRUSS CALCULATIONS SHALL BE CROSS-REFERENCED TO THE FLOOR PLANS. TO BE GIVEN TO PLAN CHECK, NOT TO BE GIVEN TO THE FIELD INSPECTOR FOR PLAN APPROVAL.

ELEVATIONS:

1. INDICATE DETAILS.

SECTIONS - DETAILS - MISC. NOTES:

1. PLEASE CALL OUT THE DETAILS .

2. ROOF PLAN / A3 ; PLEASE SHOW THE ROOF VENT SIZES AND LOCATIONS FOR ROOF ZONES B, C, AND D. IF THE INSULATION IS AT THE ROOF SHEATHING INSTEAD OF BEING AT THE CEILING, THE ROOF ISN'REQUIRED TO BE VENTILATED.

3. ROOF PLAN / A3 ; ARE THE STRIP VENTS ON THE PORCHES ON THE ROOF OR CEILINGS. PLEASE CLARIFY.

4. DETAILS / S3 ; PLEASE INDICATE THE WALL BRACING MATERIAL.

5. 5,6,7,8 / S3 ; PLEASE INDICATE "SAG-RESISTANT FOR THE ½" GYP LID. TABLE 702.3.5 FOOTNOTE D

PLUMBING PLANS:

1. PLEASE INDICATE THE ROUTE OF THE SEWER LINE ON THE SITE PLAN.

2. PLUMBING NOTE 12 / P1 ; PLEASE INCLUDE THE ICE MAKER AS REQUIRING WATER HAMMER PROTECTION. SEE MEMO DATED MARCH 6, 2008 .

3. PLEASE CHECK THE GAS PIPE SIZES. TABLE G2413.4 (1)

MECHANICAL PLANS:

1. PLEASE SIZE THE RETURN AIR DUCT AND CHECK THE SIZE OF THE RETURN AIR FILTER FRAMES. M1403.1 AND M1307.4.1.2 FOR GRILL RESTRICTION.

ELECTRICAL PLAN:

1. PLEASE PROVIDE THE OUTDOOR LIGHTING CODE CALCULATIONS.




IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 837-4910

Final Status

Task End Date Reviewer's Name Type of Review Description
05/05/2008 CINDY AGUILAR OUT TO CUSTOMER Completed
05/05/2008 SHANAE POWELL REJECT SHELF Completed