Permit Number: T08CM00922
Parcel: 12205046A

Address:
2102 N RALPH AV

Review Status: Completed

Review Details: POST 3RD PARTY REVIEW

Permit Number - T08CM00922
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/05/2008 DAVE MANN FIRE REVIEW Approved
06/10/2008 DAVID RIVERA ZONING REVIEW Denied FROM: David Rivera
Principal Planner for:

Heather Thrall
Senior Planner

PROJECT: T08CM00922, 2102 N. Ralph Avenue
5 new apartment units
Commercial Site plan, 2nd Review

TRANSMITTAL DATE: June 10, 2008

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. It is clear that the building setback has not been addressed on the site plan. In the review of the building plans it was found that the top of parapet from the finish floor is labeled as 21'-0". Detail 2 on sheet A2 of 7 of the building plan set indicates the design grade is 8 inches below the finish floor elevation. Based on this information the building setback along the north property line must be 16.25 feet from the property line. Per the site plan, the building setback along the north property line is labeled as 15.75 feet. Prior to approval of the site plan a DDO approval would be required. The parapet may be lowered 8 inches which would be sufficient in order to approve the proposed setback.

Previous Comment: Per DS 2-02.2.1.6, regarding buildings:
A) note height is from GRADE to flat roof then note height from grade to top of parapet.




RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan/building plans.
06/19/2008 LOREN MAKUS ENGINEERING REVIEW Denied June 23, 2008

T08OT00312 - Site Plan
T08CM00922 - Building Plan
T08BU00442 - Grading Plan
T08OT00649 - Floodplain Use Permit

The plans submitted for review do not appear to be updated since the most recent previous review. Please provide a clearly identified submittal for all of these plans. Clearly mark the plans that have been superseded. Include copies of any plans that have been approved by any reviewer.

Loren Makus

Final Status

Task End Date Reviewer's Name Type of Review Description
07/09/2008 DELMA ROBEY OUT TO CUSTOMER Completed
07/09/2008 SUE REEVES REJECT SHELF Completed