Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08CM00836
Parcel: 11704168A

Address:
603 N PERRY AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T08CM00836
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/14/2008 GERRY KOZIOL WWM REVIEW Approved
04/17/2008 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T08CM00836

4/20/08 603 N. PERRY

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

SITE PLAN:

1. PLEASE IDENTIFY THE LOCATION OF THE CARPORT.


FOUNDATION PLANS:

1. AN ENGINEER REGISTERED IN ARIZONA IS REQUIRED FOR THE STRUCTURAL DESIGN OF WALLS AND FENCES OVER 6' TALL.

FLOOR PLANS:

1. PROVIDE WORKING SPACE FOR THE TANKLESS WATER HEATER. (3068 DOOR…?)

2. PLEASE NOTE IF THE TUB HAS A SHOWERHEAD, A NON-ABSORBENT WALL PROTECTION(i.e. TILE, FIBERGLASS, etc.) TO NOT LESS THAN 6 FEET ABOVE THE FLOOR IS REQUIRED.

3. PLEASE INDICATE TEMPERED GLASS FOR THE 3030XO WITHIN A 24" ARC OF THE FRONT DOOR. R308.4 ITEM 6 .

STRUCTURAL PLANS:

1. AN ENGINEER REGISTERED IN ARIZONA IS REQUIRED TO DESIGN WALLS/FENCES OVER 6' TALL.

2. PROVIDE LATERAL SUPPORT FOR THE CARPORT IN BOTH DIRECTIONS..

3. A 4X4 BEAM APPEARS INADEQUATE FOR THE CARPORT. PLEASE JUSTIFY.

SECTIONS - DETAILS - MISC. NOTES:

1. 1,4 / 2 ; PLEASE INDICATE THE 3/8" OSB IS ON THE FACE OF THE STUDS.

2. 3,4 / 2 ; INDICATE "SAG-RESISTANT" GYPSUM CEILING. TABLE R702.3.5 FOOTNOTE D .

3. 4 / 2 ; INDICATE THE LATERAL BRACING OF THE PONY WALL. (FRAMED CRICKET…?)

4. SECTION A / 3 ; a. PLEASE USE A LARGER SCALE, i.e. 3/8" OR !/2" PER 1' .
b. SHOW THE REINFORCEMENT IN THE FOOTING AND THE CONNECTION OF THE STEM TO
THE FOOTING.
c. IDENTIFY THE POST / STEM CONNECTION.
d. IDENTIFY THE ROOF SHEATHING AND THE ROOFING MATERIAL.
e. IDENTIFY THE ROOF SLOPE.
f. DIMENSION THE FOOTING; THICKNESS, DEPTH, AND SIZE
g. SHOW THE LATERAL BRACING.

PLUMBING PLANS:

1. THE HORIZONTAL DRAIN FOR THE BATHTUB AND WATER CLOSET SHOULD BE SHOWN COMING FROM THE VENT NOT THE TAIL PIECES OF THE TRAPS.

2. THE CROSS SECTIONAL AREA OF THE VENTS THROUGH THE ROOF SHOULE EQUAL, OR EXCEED, THE CROSS SECTIONAL ARES OF THE REQUIRED BUILDING SEWER. UPC 904.1 .

3. STATE WHICH PLUMBING CODE YOU ARE USING.

4. PLEASE NOTE WATER HAMMER ARRESTORS ARE REQUIRED ON QUICK-CLOSING VALVES. UPC 609.10, IRC P2903.5 . SEE MEMO OF MARCH 6, 2008 .


MECHANICAL PLANS:

1. THE A/C IS REQUIRED TO PROVIDE HEATING FOR HABITABLE ROOMS. IS THIS FEDDERS UNIT A HEAT PUMP? R303.8 .


OUTDOOR LIGHTING:

PROVIDE THE OUTDOOR LIGHTING CODE CALCULATIONS.





IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 837-4910

Final Status

Task End Date Reviewer's Name Type of Review Description
04/25/2008 CPIERCE1 OUT TO CUSTOMER Completed
04/25/2008 SHANAE POWELL REJECT SHELF Completed