Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM00661
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Motel 6 #1196 - 1222 S. Freeway T08CM00661 Building Plan (2nd Review) TRANSMITTAL DATE: May 13, 2008 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the areas of revised accessibility. 2. Zoning acknowledges the receipt of an approved site plan. This plan does not show the parking area expansions to the north and south. Provide documentation that approves this expansion. If unable to provide the expansion documentation a new site plan is required meeting D.S. 2-02 requirements. It appears that the expansion may require full code compliance due to a greater than twenty-five (25) percent expansion. If documentation is provided that approved this expansion, a site plan review is still required for the parking re-strip. The parking re-strip site plan requires a fully dimensioned parking layout and is a separate review from the proposed tenant improvement. Due to the proposed restriping of existing parking a site review is required. Submit a site plan showing all fully dimensioned parking layout for site review. Include the proposed ADA changes. Provide a copy of the last approved site plan with this submittal. 3. D.S. 2-02.2.1.8 North of the existing trash area there are ten (10) vehicle parking spaces called out with only nine (9) shown, please clarify. 4. D.S. 2-02.2.1.8 South of the existing trash area there are six (6) vehicle parking spaces called out, the western most vehicle parking space does not meet minimum width requirements or the maneuvering requirements. See D.S. 305.2.1.B.1 and D.S. 3-05.2.2.D. 5. D.S. 2-02.2.1.12 It is not clear how the proposed sidewalk and truncated domes works with the proposed accessible route located near the northwest corner of the building. Is this sidewalk flush with pavement or raised? Is there a ramp? 6. D.S. 2-02.2.1.12 It appears that the proposed crosswalk that will connect the pool to the hotel encroaches into the twenty-four (24) foot parking area access lane (PAAL). Provide a dimension for the PAAL to the north. Per D.S. 3-05.2.1.C.1 the minimum width of a two-way PAAL is twenty-four (24) feet. 7. D.S. 2-02.2.1.12 The proposed crosswalk that connects the pool to the hotel, north end is required to be a sidewalk, physically separated from the PAAL and parking spaces, the depth of the parking space area. 8. Again this site requires a site review due to the changes in parking layout, not a tenant improvement. Additional comments may be forth coming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t08cm00661-2nd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 05/13/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 05/19/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | ZONING ADA COMMENTS MADE ON 13 MAY 08 ARE APPLICAPABLE 5. D.S. 2-02.2.1.12 It is not clear how the proposed sidewalk and truncated domes works with the proposed accessible route located near the northwest corner of the building. Is this sidewalk flush with pavement or raised? Is there a ramp? |
| 05/23/2008 | PAUL MACHADO | ENGINEERING | REVIEW | Needs Review | SITE PLAN PORTION REMOVED PER LETTER IN SIRE - WORK FOR PERMIT INTERIOR ONLY |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/23/2008 | BETH GRANT | OUT TO CUSTOMER | Completed |