Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM00604
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/22/2008 | MARTIN BROWN | FIRE | REVIEW | Approved | |
02/22/2008 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | IMPACT FEE'S DO APPLY; WEST DISTRICT; 1,200 SQUARE FEET OF RETAIL? SPACE; $4,771.20 - PLEASE NOTE THERE WILL BE A 2.54% INCREASE IN IMPACT FEE'S ON 3/10/08 |
02/27/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A0: VERTICAL GRAB BAR REQUIRED IN RESTROOM PER ANSI A117.1, SECTION 604.5. 2. CITY OF TUCSON REQUIREMENT TO HAVE ALL LETTERING ON PLANS MINIMUM OF 1/8". YOU MAY APPEAL THIS THROUGH THE BUILDING OFFICIAL, JESSIE SANDERS. 3. PROVIDE SHELL BUILDING DRAWINGS. 4. INDEX SHEET: CHANGE BUILDING AREA TO INCLUDE ENTIRE SHELL BUILDING. OCCUPANT LOAD CAN BE BASED ON TENANT SPACE AREA. |
03/03/2008 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | ELECTRICAL NOTES; MUST PROVIDE SERVICE ONE LINE DIAGRAM SHOWING SIZE,AMPACITY ,ETC AND HOE CONNECTED TO SHELL SERVICE. THERE WERE NO SHELL DRAWINGS PROVIDED WITH THIS PLAN. RAY MAJUTA,DSD,ELECTRICAL PLANS EX. 3/4/08 |
03/18/2008 | ROBERT SHERRY | WATER | REVIEW | Denied | Provide a copy of the approved drawings for the shell package of the building to establish the existing conditions for the water meter and any backflow devices serving this tenant space. Reference: Sections 106.1 and 106.3, IBC 2006 |
03/18/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide a copy of the approved drawings for the shell package of the building to establish the existing conditions of the tenant space and the shared plumbing systems. Reference: Sections 106.1 and 106.3, IBC 2006. 2. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). (A 3/32", all-upper-case font may be allowed with an appeal to the building official.) Reference: Section 106.1.1, IBC 2006. 3. Show that the location of the public restroom complies with Section 1104.5, IBC 2006. 4. Provide a vacuum relief for a storage-type water heater located above any fixture outlets. Reference: Section 608.7, UPC 2006 5. Verify that the provided water calculations are consistent with the shell building water calculations. Reference: Sections 610.4 and 610.5, UPC 2006. 6. Provide upper terminal cleanouts on horizontal drainage pipes exceeding 5 feet in length (horizontal drain lines serving sinks require cleanouts regardless of length). Reference: Section 707.4, UPC 2006 7. Provide a direct waste connection for the wash and rinse sections of the 3-compartment sink, with an indirect connection for the sanitizing compartment only. Reference: Sections 304.0 and 801.2.3, UPC 2006. |
03/18/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide a copy of the approved drawings for the shell package of the building to establish the existing conditions of the tenant space. Reference: Sections 106.1 and 106.3, IBC 2006. 2. Provide calculations demonstrating adequate ventilation. Reference: Section 401.2, IMC 2006. |
03/20/2008 | GERRY KOZIOL | WWM | REVIEW | Denied | 1:PAPA MURPHY'S-TAKE 'N' BAKE-ISSUED W/ GREASE INTERCEPTOR-PREP SINK INDIRECT 2: NEED TO SUBMIT WASTEWATER APPROVED SHELL PLUMBING DRAWING & REVISED WASTEWATER APPROVED DRAWING (PERMIT #PT07S02397 & PT07S04075) FOR CREDIT EVALUATION |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/25/2008 | VFLORES1 | OUT TO CUSTOMER | Completed |
03/25/2008 | SHANAE POWELL | REJECT SHELF | Completed |