Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM00484
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/13/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
06/24/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
06/24/2008 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
06/24/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Section 910.4, UPC 2006 requires that each waste pipe and trap be at least two pipe sizes larger than the fixture tailpiece. The combination waste and vent system shown in the previous revision would have been correct if the fixture tailpieces had been shown (and scheduled) as being 2" in size. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/30/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
06/30/2008 | SUE REEVES | REJECT SHELF | Completed |