Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM00484
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/01/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. INCORPORATE NEW FITTING ROOM CUTSHEET INFORMATION (PLANS, PERTINENT DETAILS) ONTO SUBMITTAL DRAWING SET. |
05/12/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. A 3/32" font may be allowed with an appeal to the building official. http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/Petition_of_Appeal.pdf 2. Exhaust fan EF-11 shall operate whenever air is being supplied to the restroom (i.e. during all hours of store operation), not just when the restroom is being occupied. Reference: Section 403.2.1, IMC 2006. 3. Correct the label for the TLE exhaust fan EF8 on sheet MAC1. Reference: Section 106.3.1, IMC 2006 |
05/13/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. A 3/32" font may be allowed with an appeal to the building official. http://www.tucsonaz.gov/dsd/Forms_Fees___Maps/Applications/Petition_of_Appeal.pdf 2. The waste and vent isometric for the temporary vision center shows a simplex lift station for the two sinks. A lift station in a public use situation requires either a duplex system or an appeal to the building official if a simplex system is to be used. Reference: Section 710.9, UPC 2006. 3. Provide a check valve and a full-way gate or ball valve for the discharge of the lift station. Reference: Section 710.4, UPC 2006. 4. Show where and how the discharge of the lift station is to be connecting to the building drain. Provide information to demonstrate that the connection point is adequately sized. Reference: Sections 710.5 and 805.0, UPC 2006. 5. Provide an audible and visual alarm for the lift station per Section 710.9, UPC 2006. 6. Indicate the size of the tailpiece used for FS-1 in the combination waste and vent system for the refrigerated cases (4/P1). The Floor/Roof Drain Schedule (P3) does not clearly indicate the tailpiece size for the floor sink FS1. The specified model numbers for both the Josam and Sioux Chief floor sinks are not shown in their respective on-line catalogs and the Oatey catalog indicates that the model 42722 floor sink has a 4" tailpiece. Reference: Section 910.4, UPC 2006. 7. Specify the type of backflow preventer to be used for the connection of the Pharmate RO System. Reference: Sections 602.3, 603.0, and Table 6-2, UPC 2006. (2/MPH1) |
05/16/2008 | TERRY STEVENS | ZONING | REVIEW | Approved | |
05/27/2008 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 520.837.4907 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Compile complete sets for final approval and signature. 2. It appears that the compressor assembly is aprox. 50' from MSWB, not 150'. Please rework fault calculations and provide fault current rating of equipment. 3. Add Existing Panel HR to HB Panel Schedule electrical load. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/12/2008 | VFLORES1 | OUT TO CUSTOMER | Completed |
06/12/2008 | SHANAE POWELL | REJECT SHELF | Completed |