Permit Number: T08CM00457
Parcel: 110055340

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T08CM00457
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/19/2008 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied 1. PRIVATE BATH MUST BE ADA ADAPTABLE.
2. ALL COUNTER MOUNTED SINKS TO BE ACCESSIBLE AT 2'-10" AFF.
3. DRINKING FOUNTAIN TO BE HIGH/LOW OR OBTAIN AN APPEAL FROM BUILDING OFFICIAL
02/19/2008 ROBERT SHERRY WATER REVIEW Approved
02/19/2008 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
02/19/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Coordinate the riser diagrams (water and waste &vent) with the plumbing plans.
2. Show how the steam generator is to be installed, e.g. the water supply, the drain and the pressure relief. Show the terminations of the drain and pressure relief piping.
3. Provide information to show that the proposed water cooler is listed. Statements such as, "manufactured to comply with the standards of Underwriter's Laboratories" may not be the same as actually being listed.
4. Provide information to show that the water heater tank in the water cooler does not require a temperature/pressure relief.
5. Show what the tankless water heater will be serving. Also, what is the source for the existing hot water?
02/22/2008 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
02/22/2008 GERARDO BONILLA OUT TO CUSTOMER Completed