Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T08CM00402
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/20/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
| 03/28/2008 | HEATHER THRALL | ZONING HC SITE | REVIEW | Denied | Please see zoning review comments. Thank you. |
| 03/28/2008 | HEATHER THRALL | ZONING | REVIEW | Denied | Heather Thrall, Senior Planner, Zoning Review T08CM00402, 6880 E. Broadway, C-2 and R-1 zoning 1) This project was reviewed for a Tenant Improvement to allow a school use on the existing developed site. Some minor site changes were also reviewed for the proposed school use. The codes used in this review were the Land Use Code (LUC), Development Standards (DS), and American National Standards Institute (ANSI). 2) per the Zoning Administrator, a 6' wide sidewalk will be required along the drop off parallel parking spaces. The plan shows a 4' wide walk. Modify the sidewalk width to 6' anywhere along the drop off spaces. 3) Please show the zoning boundary line between the C-2 and R-1 zones on the site. 4) Please provide the last Certificate of Occupancy for the site. I need to see that the variance to reduce the width of the PAAL at the west side of the site was effectuated with the issuance of a C of O/building permit, etc. 5) Please provide the last approved site plan for the site. I just need to make sure that the site plan provided matches - overall - the last approved site plan for areas other than the new drop off lane. 6) Please provide the variance case number and notes of approval -get the official records please - to reduce a PAAL to 17' wide on this property. 7) please show maneuverability of the last parallel parking space to the south drop off lane - it's bounded by a traffic island. 8) please provide directional arrows on the pavement for the public to properly access the drop off lanes 7) Please email me for an appointment at Heather.Thrall@tucsonaz.gov to go over the above. |
| 03/28/2008 | HTHRALL1 | ADA | REVIEW | Passed | |
| 04/08/2008 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | The following Tucson Code (Sec. 25-38.b) needs to be addressed via a Traffic Statement or Traffic Impact Analysis. If needed a meeting can be scheduled to discuss any questions regarding this code. Sec. 25-38. Special requirements in residential districts. (a) Curb cuts and driveways shall conform to the following requirements in all residential zoned districts: Minimum curb cut width . . . 10 feet Maximum curb cut width . . . 20 feet Maximum curb cut width for 2 adjoining properties . . . 30 feet Minimum distance between curb cuts . . . 12 feet Minimum distance of curb cut from street light standards, or catch basins . . . 5 feet Minimum distance of curb cut from a fire hydrant of city water hydrant . . . 20 feet Minimum distance of curb cut from end of a curb return . . . 4 feet OR from a curb line or a cross street at a street intersection, whichever is more restrictive . . . 20 feet See Tucson Code Chapter 23, Land Use Code, particularly Section 3.2.14 and Development Standards, Section 3, Transportation, for additional requirements and standards. (b) Any nonresidential use which would generate more than five (5) times the amount of traffic that would be generated as a result of (a) the existing use of the property if developed for residential use, or (b) the predominant use on the residential block if the property is vacant, shall not have access to an interior residential neighborhood street after June 1, 1998. (1) "Interior residential neighborhood street" as used in this subsection shall include any block consisting entirely of residentially zoned properties except for streets which have been designated as arterial or collector streets in the major streets and routes plan. (2) A waiver to this requirement may be granted at the discretion of the director of the department of transportation where justified by a traffic mitigation plan or unique circumstances which substantially achieve the level of traffic on the affected area as required by this subsection. No waiver may be granted without providing notice and an opportunity for comment to the residential property owners on the block for which the waiver is proposed. Any decision of the director of the department of transportation may be appealed to the mayor and council by the applicant or an affected property owner. (Ord. No. 2657, § 1, 10-19-64; Ord. No. 9065, § 1, 6-1-98; Ord. No. 9065, § 1, 6-1-98) If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov |
| 04/10/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | Provide the last approved site and landscape plan for reference. Review will continue when approved documents are included with submittal. Additional comments may apply |
| 04/10/2008 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 04/30/2008 | LOREN MAKUS | ENGINEERING | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/30/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |