Permit Number: T08CM00336
Parcel: 13707034J

Address:
302 W IOWA ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T08CM00336
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2008 BIANCA RAMIREZ ENGINEERING REVIEW Approved February 8, 2008
FLOODPLAIN USE PERMIT # T08OT00272
PROJECT ADDRESS: 302 W Iowa Street
APPLICANT'S NAME: La Causa Construction
PROPERTY OWNER: Chicanos Por La Causa


This parcel lies in a FEMA X (unshaded) Zone map number 040076 C 2236K, effective date February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

302 W Iowa Street, Tucson, AZ 85706, ARCADIA PTN S100' E55.21' LOT 4 BLK 1. In a portion of Township 15 South, Range 13 East, Section 1, for the construction of a new single family residence..


The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) The proposed single family residence has an established minimum finished floor elevation of 2475.30 per Record of Survey - Liberty Corners 6 Lots. Per S06-191.

4) The regulatory elevation of the residence per Record of Survey - Liberty Corners 6 Lots (S60-191) must be at an elevation no less than 2475.30. Per basis of elevation: Chiseled 'X' on the northwest corner of a catch basin at the northeast corner of Irvington and Liberty Avenue. Elevation = 2471.124 per City of Tucson Datum (NAVD 1988), Survey Field Book 2155, Page 8.

5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT00272 FOR INFORMATION PLEASE CALL 791-5550."

6) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to electrical inspection or habitation. The Elevation Certificate must include the identity and elevation of the finished floor, equipment/machinery servicing the home as well as the identity and location of all other equipment/machinery servicing the home.

7) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.

8) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

9) See the associated activity T08CM00336.


This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of approval. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 2 Day: 8 Year: 2009

APPLICANT/CONTRACTOR: La Causa Construction
ADDRESS: 200 N Stone, Tucson, Arizona 85701
PHONE: (520) 882-0018
OWNER: Chicanos Por La Causa
ADDRESS: 200 N Stone, Tucson, Arizona 85701
PHONE: (520) 882-0018


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.