Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM00267
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/25/2008 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Denied | 1. NEED DETAILED, 24 X36 SITE PLAN SUBMITTED SHOWING ALL ACCESSIBILITY ROUTS TO SPACE WITH SLOPES AS PER ANSI 117.1. IDENTIFY THE SPACE AND IDENTIFY THE ROUTES AND IDENTIFY THE PARKING SPACES AND THEIR ROUTES. 2. CANNOT ACCESS TOILET THROUGH KITCHEN; IBC SECTION 2902.4 3. NEED TWO LEVEL EWC AS PER IBC SECTION 1109.5.1, TABLE 2902.1 AND ANSI 117.1, SECTION 602.4 4. MINIMUM SIZED LETTERING ON ALL DRAWINGS RO BE 1/8" |
01/25/2008 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
01/29/2008 | GERRY KOZIOL | WWM | REVIEW | Approved | |
01/29/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
02/12/2008 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 520.837.4907 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. It appears that the clothes dryer should be on a maximum overcurrent protective device of 25A, not 30A. Reference NEC 422. 2. Provide conductor size for A-40,42. 3. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). Reference Section 106.1.1, IBC 2006. 4. Provide cut sheets for neon signs. Reference Sheet E1. 5. Establish grounding of the telephone system. Reference NEC 800.100. |
02/25/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
02/25/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Clarify the connection point for the water supply from the building service. Reference Section 103.2.3, UPC 2006. 2. Provide listing information for the hand sinks (P-4), the 3-compartment sink (P-10, and the prep sink (P-11). Reference Section 103.2.3, UPC 2006. 3. The design of the water heater piping, with a valve located between the water heater and the expansion tank, makes it impossible for the expansion tank to accommodate the thermal expansion of the water in the water heater, as intended by Section 608.3, UPC 2006. 4. Provide upper terminal cleanouts on horizontal drainage pipes exceeding 5 feet in length (horizontal drain lines serving sinks require cleanouts regardless of length). Reference Section 707.4, UPC 2006. 5. Provide a direct waste connection for the wash and rinse sections of the 3-compartment sink, with an indirect connection for the sanitizing compartment only. Reference Sections 304.0 and 801.2.3, UPC 2006. |
02/25/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide a mechanical plan to show how the existing mechanical system will be modified for the new occupancy. Reference Section 106.3.1, IMC 2006. 2. Provide calculations demonstrating adequate ventilation. Reference Section 401.2, IMC 2006. 3. Show the size, route, and termination of the dryer exhaust duct. Reference Sections 504.1, 504.2, and 504.4, IMC 2006. 4. Show how the dryer installation complies with Section 504.5, IMC 2006. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/05/2008 | CPIERCE1 | OUT TO CUSTOMER | Completed |
03/05/2008 | SHANAE POWELL | REJECT SHELF | Completed |