Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T08CM00263
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/17/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | PREVIOUS COMMENTS NEED CLEARIFICATION: 10D. NO COPY OF EMAIL ENCLOSED. 10E. PEDESTRIAN CONNECTION TO ADJACENT RAMADA INN DOES NOT WORK ON THE NEW SIDE AND IS INCOMPLETE ON THE EXISTING SIDE. PROVIDE A NEW MARKED CROSSING WITH RAMPS AND DETECTABLE WARNINGS AS PER ICC/ANSI 117.1, SECTION 405 AND 406. SHOW LARGE SCALE PLAN OF NEW MARKED CROSSING PLUS NEW PARKING LAYOUT FOR EXISTING RAMADA. |
| 06/24/2008 | HEATHER THRALL | ZONING | REVIEW | Denied | TO: Development Services Department, Plans Coordination Office FROM: Heather Thrall, Senior Planner PROJECT: T08CM00263, 665 N. Freeway, New Country Inn Hotel, 2nd Review TRANSMITTAL DATE: June 24, 2008 COMMENTS: Please resubmit revised drawings and response letter addressing all Zoning Review comments OR email me for a counter appointment after all other divisions have completed review of this submittal. 1. Staff acknowledges a lot split - case S08-06, in process and approved by all DSD divisions. After legal descriptions recorded and new address obtained, return to zoning counter with 3 copies of all documents for zoning staff to finalize the split. 2. (Per last review) Per DS 2-02.2.1.7, regarding setbacks: A) in street front setbacks notes section, add note "measured from back of future curb." B) as hotel literally goes right up to electrical easement at west, provide building setback dimension -for records and inspections - from point of the building directly abutting electric easement (northern most cornice at west patio) to the west property line. This is to help ensure no part of the building encroaches into that electric easement. 3. Per DS 2-02.2.1.11, regarding PAALs A) A cross ACCESS agreement is required between existing hotel and new hotel, as plan shows access to parking for existing Ramada Inn via travel across Country Inn site. Provide copy & note cross access agreement and recordation information on plan. 4. Per DS 2-02.2.1.12, regarding handicapped and pedestrian circulation: A) I acknowledge your response regarding gates. As typical gate width is not dimensioned, give note "All pedestrian gates are of 4' width for pedestrian access ". B) Response indicates a pedestrian connection provided to adjacent Ramada Inn, per DS 2-08.4.1. It is difficult to determine how connection accomplished to Ramada Inn pedestrian route. Appears on drawing the crosswalk just leads to parking. Does the crossing lead to an actual sidewalk serving the Ramada Inn? - please show. 5. Per DS 2-02.2.1.20, please provide docket and page for water easement. 6. Further review comments may be forthcoming, depending upon responses provided. I may be reached at Heather.Thrall@tucsonaz.gov or at 837-4951. IF YOU PREFER, I AM WILLING TO DO A FINAL REVIEW IN A MEETING. EMAIL ME FOR A TIME. HCT C:\planning\site\DSD\T08CM00263 665 N. Freeway 2.doc RESUBMIT THE FOLLOWING: Revised site plan and additional requested documents |
| 06/26/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approv-Cond | Ensure that all changes to the site plan are reflected on the landscape & grading plans. |
| 06/26/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: June 26, 2008 SUBJECT: Site Plan TO: Kenta Delph LOCATION: 665 N Freeway, T14S, R14E, Section 18, Ward 5 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM00263 (Second Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the SP. Site Plan: 1. Provide note on site plan indicating that demolition permit will be obtained for demolition work OR provide demolition permit number on site plan for demolition work. 2. See Ron Brown for comments regarding handicap access requirements. 3. Complied. 4. Complied 5. Complied 6. Complied 7. Complied 8. Complied 9. Complied 10. Complied 11. Complied 12. Complied 13. Complied 14. DS Sec.2.02.2.1.A.16: Show roof down spout locations along west side of building. Indicate splash pads and provide detail for splash pads or provide proposal for erosion protection. 15. Complied 16. Complied 17. Verify that all easements of record have been graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. Provide docket and page for water easment indicated along east property line. 18. Provide contour interval on plan below the scale located near the north arrow and indicate the location of benckmark on the site plan for reference. 19. Complied 20. Complied 21. Complied 22. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 23. Complied 24. Complied 25. Complied 26. DS Sec.2-02.2.1.A.8: Revise handicap post and sign. Post is to be a minimum of 7'0" to finished grade from the bottom of sign and the sign should read under handicap logo DISABLED PLATE OR PERMIT ONLY DO NOT BLOCK ACCESS AISLE $518 FINE T.C.C. 20-222 27. Complied 28. Complied 29. Complied 30. Complied 31. Provide existing and proposed site visibility triangles on site plan. Verify sight visibility triangle dimensions indicated and revise keynote 51 to call out the same dimensions that are called out on plan. 32. Complied 33. Complied 34. Complied 35. Complied 36. Complied 37. Complied 38. Additional comments may be forthcoming. Drainage Report: Please include a response letter to the comments along with the corrected copies of the Drainage Report. 1. Complied 2. Complied 3. Complied 4. Complied 5. Complied 6. On page 12 of the drainage report verify that 0.6 cfs for east channel is accurate. Numbers are still not matching. If revised please explain in response letter. Verify that 13 is correct for 10-year and verify accuracy of table. 7. Complied 8. Complied 9. Complied 10. Complied a. Complied b. Complied c. Complied d. Complied 11. Complied 12. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/07/2008 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 07/07/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 07/07/2008 | DELMA ROBEY | REJECT SHELF | Completed |