Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM00198
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/17/2008 | GERRY KOZIOL | WWM | REVIEW | Approved | |
04/23/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 4-25-08 Activity: T08CM00198 Address: 3272 E. Via Palos Verdes Applicant: Karen Merodias DeCook Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. 3. As of 6/12/2007 the City of Tucson has adopted the 2006 IRC. Correct all 2003 references. SITE PLAN: 4. Specify the location of the swimming pool barrier to comply with AG105.2 as amended. STRUCTURAL PLANS: 5. Justify the floor joists specified. 6. Justify the hip rafters specified. 7. Verify the ledger and wall heights to coincide with the intended slope. 8. Specify the quantity and spacing of the fasteners to connect the ledgers to their supporting members. PLUMBING PLAN: 9. Provide a fixture unit schedule for the entire property (including existing) UPC Tables 6-5 and 7-3. 10. Specify the diameter of the water line from the meter, UPC Table 6-6. 11. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, UPC 609.10. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/06/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
05/06/2008 | SHANAE POWELL | REJECT SHELF | Completed |