Permit Number: T08CM00177
Parcel: 14001050A

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T08CM00177
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/11/2008 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Dusty Duds Excavating
T08CM00177
Site Plan (2nd Review)

TRANSMITTAL DATE: September 11, 2008

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance.

2. D.S. 2-02.2.1.A.7 Zoning acknowledges that the setback dimension from the property line is shown correctly. Under "SITE DATA:, SETBACKS, FRONT (west)" the setback listed is not correct. Per LUC Section 3.2.6.5.A. Within established areas, the front street perimeter yard is twenty (20) feet or one and one-half (1 1/2) the height of the proposed wall (H), measured from the street property line, whichever is greater, up to a maximum of ninety (90) feet. The required setback should be listed as twenty (20) feet. Also remove the reverence "(1) - from back of future curb.

3. Once the above comment has been addressed zoning will provide an over the counter review, please call or email to schedule an appointment.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t08cm00177-2nd

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
09/12/2008 ANDREW CONNOR NPPO REVIEW Approved
09/12/2008 ANDREW CONNOR LANDSCAPE REVIEW Approved
09/17/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 1. Generally, this type of modular building has a finished floor well above the finished grade whaich requires an extensive ramp system to be constructed for accessibility. Verify the finish floor elevation and comply with the IBC 2006, Section 1105 and ICC 117.1, Sections 302 and 303.
2. Show Accessible Parking Sign location on site plan.
3. Detectable Warnings are not required by code for this parking and accessibility layout, Owner option.
09/22/2008 DROBEY1 PLUMBING-COMMERCIAL REVIEW Needs Review