Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM00116
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/17/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 1/18/08 Activity: T08CM00116 Address: 4901 E. 17th St. Applicant: Dan Law Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. SITE PLAN: 3. Specify the location of utility lines and meters from property line to building, R106.1.1. STRUCTURAL PLANS: 4. Specify the size of collar ties to be installed on the shop roof along with the connection requirements to the rafters, R802.3.1. 5. Provide an attic space ventilation calculation and note the size and location of all attic vents needed to comply, R806.2. 6. Truss calculations must be signed, dated and wet-sealed by an engineer who is registered in Arizona. Truss calculations shall be cross-referenced to the floor plans. Note: Due to the nature of the proposed low-profile truss design, a deferred submittal will not be acceptable for this project. MECHANICAL PLAN: 7. Show the dryer vent size and location for venting to the exterior (max 25' w/bend reductions), M1502.2, M1502.6. ELECTRICAL PLAN: 8. Show receptacle outlets at bar counter spaces wider than 12" so that no point along the wall line is more than 24" from a receptacle outlet, E3801.4.1. 9. Receptacles mounted below the countertop shall not be located where the countertop extends more than 6 inches beyond its support base, E3801.4.5. INTERNATIONAL ENERGY CONSERVATION CODE: 10. Specify a "U" factor and solar heat gain coefficient of the windows and doors that meets or exceeds the requirements of N1102.1. The simplified prescribed energy value for climate zone 2B glazing and skylights is U=0.75, the default SHGC is 0.40. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/18/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |