Permit Number: T08CM00109
Parcel: 140132040

Address:
2254 E PINON DR

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU

Permit Number - T08CM00109
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/18/2008 HEATHER THRALL ZONING REVIEW Approved
01/18/2008 LOREN MAKUS ENGINEERING REVIEW Approved
01/18/2008 HEATHER THRALL NPPO REVIEW Passed
01/18/2008 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 1/18/08
Activity: T08CM00109
Address: 2254 E. Pinon Dr.
Applicant: Jessica Morales

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.
2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

FOUNDATION PLANS:
3. All exterior walls require continuous concrete footings min. 12"wide x 12" below grade with treated sill plates and anchor bolts per R319.1 & R403.1.6 (including carport and porch enclosures).

STRUCTURAL PLANS:
4. Provide additional roof framing information to verify design criteria requirements for conditioned living space, R301.

SECTIONS - DETAILS:
5. Provide a cross section detail for the in-fill walls to include a continuous load path from the roof to the foundation, R602.10.8.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review